Oil-free magnetic-bearing Turbocor compressors in a central process chiller: 60 to 240 tons per unit, water-cooled or with remote air-cooled condensers.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Central Chiller | Centrifugal Central | 60 to 240 Tons | 24 |
Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.
Twenty-four models in two condenser styles. The TCW models are water-cooled and the TCR models use remote air-cooled condensers. The 300 and 350 frames carry one Turbocor compressor on one circuit; the 600 and 700 frames carry two on independent circuits.
The compressor is the story. A Turbocor is a variable-speed centrifugal compressor on magnetic bearings, driven by a brushless DC motor, with no oil in the system at all. Thermal Care publishes 74 dBA per compressor and a soft start that limits inrush current.
Capacity is published at a 50°F set point and 60°F return on 85°F condenser water for the TCW and 95°F condenser air for the TCR, on R-513A or R-134a. Each frame covers a published range, 30 to 90 tons on the TCW300 up to 40 to 240 tons on the 700 frames; each unit page gives one configuration, 60 to 240 tons.
The set point starts at 40°F. Thermal Care lists 40 to 75°F on the TCW. For the TCR the series table says 45 to 75°F and the unit pages 40 to 75°F. The TC is a chilled-water machine, not a glycol plant.
Magnetic bearings, variable speed, no oil: the central chiller for a plant that runs warm process water around the clock.
Request a Quote
A plant that runs chilled water at 50°F or warmer, all year, at varying load, is where an oil-free centrifugal earns its price. It unloads by slowing down rather than by cycling, and at part load its efficiency improves. Below about 40°F that edge runs out, which is why Thermal Care's set point range stops there and why a glycol process belongs on a scroll-compressor TSE instead.
Thermal Care lists no tank or process pump on the TC, so it works with a pump-tank station or the plant's own pumping. The single-circuit models fit through a standard 36-inch door, which makes a mechanical-room replacement simpler than the tonnage suggests. The tonnage and capacity guide explains how the load should be counted.
Every part-number page below names the Temptek unit we supply in its place, sized to cover the published 50°F capacity: a Temptek TTI water-cooled central chiller for the TCW models and an MA chilling module with a remote condenser for the TCR. The 200 and 240-ton models are beyond any single Temptek unit, so their pages point to the add-on module range on our sister site.