1-805-484-2992

Quotes - Sizing - Sales

TSER050D

Thermal Care
Product Type Capacity Refrigerant
Central Chiller Remote Condenser 50 Tons @ 50°F R-454B or R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n TSER050D as shown on this page.

Replacement chiller for the Thermal Care TSER050D

Description

The Thermal Care TSER050D is a scroll central chiller with a remote air-cooled condenser from the Accuchiller TSE Series. Thermal Care publishes it at 50 tons (176 kW) at 50°F set point, 60°F return, 95°F condenser air, with a 20 to 80°F set point range. It runs 2 scroll compressors on each of two refrigeration circuits, on R-454B or R-410A. An integral tank is an option: 275 gallons with process and chiller pumps as standard, or 400 gallons on the high-flow package. Thermal Care pairs it with the KCL074 remote air-cooled condenser. Replacement: we supply the Temptek MA-50-RC-CC, an air-cooled chilling module with a remote condenser rated 50 tons at 50°F, against the 50 tons Thermal Care publishes for this unit at 50°F. Both makers rate at 50°F leaving fluid, so the comparison is like for like. It is refrigeration only, like this chiller without its tank option, and works with a pump-tank station. It keeps more than one refrigeration circuit, as this unit has.

Product Overview

Part Number:
TSER050D
Manufacturer:
Thermal Care
Replacement Unit:
Temptek MA-50-RC-CC

Published Capacity

Cooling Capacity:
50 tons (176 kW)
Rating Basis:
50°F set point, 60°F return, 95°F condenser air
Set Point Range:
20 to 80°F

Configuration & Specifications

Compressor:
Scroll
Compressors:
2 + 2 on two circuits
Refrigeration Circuits:
Two
Refrigerant:
R-454B or R-410A
Condenser:
Remote Air-Cooled
Evaporator:
Stainless Steel Brazed Plate
Controls:
PLC, Color Touch Screen

Pump & Reservoir

  • Tank Option, Standard Flow: 275 gallons, 10/3 hp process / chiller pumps
  • Tank Option, High Flow: 400 gallons, 15/3 hp process / chiller pumps

Electrical

  • Voltage: 460V
  • Phase: Three Phase
  • Frequency: 60 Hz
  • Minimum Circuit Ampacity: 99 A
  • Maximum Overcurrent Protection: 110 A

Connections

Process Connections:
3 in
Refrigerant Discharge Line:
1-3/8 in
Refrigerant Liquid Line:
1-1/8 in
Remote Condenser:
KCL074
Condenser Fans:
4

Dimensions & Weight

Dimensions (L x W x H):
81 x 48 x 68 in
Shipping Weight:
2,091 lbs (948 kg)
Operating Weight:
2,157 lbs (978 kg)

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales