Replacement unit for the Thermal Care TSE Series Remote Air-Cooled

TSE Series Remote Air-Cooled

The TSE central chiller with its condensers outdoors: 10 to 158 tons, single or dual circuit, each paired with its own Thermal Care remote condenser.

PRODUCT TYPE CAPACITY MODELS
Central Chiller Remote Condenser 10 to 158 Tons 18

Specifications


Configuration & Size

Capacity:
10 to 158 Tons at 50°F
Models:
18 part numbers
Compressor:
Scroll, 2 per circuit
Process Connections:
1-1/2 to 6 in
Refrigerant:
R-454B, R-410A

Construction

  • Scroll compressors, 2 per circuit
  • Matched KCM or KCL remote condensers
  • Stainless brazed plate evaporators
  • Electronic expansion valves
  • Optional integral tank and pumps

Ratings

  • Rated at 50°F set point, 60°F return
  • 95°F condenser air
  • R-410A or R-454B
  • Power: 460/3/60 published

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

TSE Remote Air-Cooled Central Chillers, 10 to 158 Tons

Central Capacity Without a Cooling Tower

Eighteen models, single or dual circuit. The TSER010S to TSER080S carry one refrigeration circuit and the TSER020D to TSER160D two, each with two scroll compressors per circuit into stainless steel brazed plate evaporators.

Every model has a matched condenser. Thermal Care's series table pairs each TSER with a KCM or KCL remote air-cooled condenser, from the two-fan KCM014 on the TSER010S to the twelve-fan KCL224 on the TSER160D, and lists the refrigerant discharge and liquid line sizes.

Capacity is published at a 50°F set point, 60°F return and 95°F condenser air, from 10 tons on the TSER010S to 158 tons on the TSER160D, on R-410A or R-454B, with a 20 to 80°F set point range.

The same tank options as the water-cooled TSE. A standard reservoir of 275 to 1,000 gallons or a high-flow reservoir of 400 to 1,000 gallons, each with process and chiller pumps, sized with the chiller.



industrial rooftop with a louvered air-cooled unit and large pipes

Scroll compressors indoors, matched remote condensers outdoors, and no tower water to treat.

Request a Quote

TSE Series Remote Air-Cooled Applications

Plastics plant headers
Plastics plant headers
Roof-mounted condensers
Roof-mounted condensers
Cold-climate plants
Cold-climate plants
Redundant circuits
Redundant circuits

schematic of the TSE series Remote Air-Cooled circuit, showing where the process fluid and the condenser heat go

No Tower, but Longer Lines

A remote air-cooled TSE gives a plant central chilled water without a cooling tower, its water treatment or its winter freeze-up risk. The chiller, tank and pumps stay in the mechanical room; the condensers go on the roof or a pad, and the refrigerant lines between them become part of the plant.

On a dual-circuit TSER each circuit has its own lines; for the TSER160D Thermal Care lists 2-1/8 inch discharge and 1-5/8 inch liquid connections. Line length and lift affect capacity and oil return, and a replacement is the time to decide whether the old condensers and lines are reused or replaced with the chiller. The indoor vs outdoor installation guide covers the trade-offs.

Every part-number page below names the Temptek air-cooled chilling module we supply in its place, with a remote condenser, the same amount of circuits where Temptek builds it, and sized to cover the published 50°F capacity.
Call and talk it through with an engineer: 1-805-484-2992

TSE Remote Air-Cooled: Installation Questions

Only after they are checked against the new module, and they are often replaced with the chiller. Thermal Care paired each KCM or KCL condenser with one TSER for its refrigerant and capacity; the TSER010S takes a two-fan KCM014 and the TSER160D a twelve-fan KCL224. The MA module we supply comes with a remote condenser of its own, so the question is whether reusing the old one saves anything once its age, coil condition and refrigerant are weighed. The lines are a separate decision: if they are sized and routed correctly, they may stay. Send photos of the condenser nameplates and the line route.

It appears to be a printing error on those unit pages. The TSER020D, TSER030D and TSER040D pages show TSER020S, TSER030S and TSER040S in their specification blocks, while the page address, the title and Thermal Care's series table all give the D model. We list them as D units. The nameplate settles it on site: a D unit has two refrigeration circuits with two scroll compressors on each, four in all, and two sets of refrigerant lines to the roof. Getting this wrong changes the replacement, since the circuit count carries over where Temptek builds it.

A little over a minute per degree at full load. A 275-gallon tank of water holds about 2,290 BTU per °F, and the TSER010S's 10 tons is 2,000 BTU per minute, so with the compressors off the tank warms just under 1°F each minute. The storage figure comes from the constant behind the standard water heat formula, close to 8.3 BTU per gallon for every degree of change, and a glycol mix stores somewhat less. That is enough to smooth compressor staging and a short restart, not to carry a process through a power cut. The MA module we supply in place of a TSER is refrigeration only and works with a pump-tank station, so this volume has to be provided there.

The published 50°F capacity, the remote-condenser arrangement and, where Temptek builds it, the circuit count; the integral tank does not. The 20-ton TSER020D maps to the MA-20-RC-CC at 23 tons, and the 158-ton TSER160D to the MA-180-RC-CCC at 180, about 15% and 14% over. If the plant relies on running one circuit during a fault, confirm that for the MA offered.