The TSE central chiller with its condensers outdoors: 10 to 158 tons, single or dual circuit, each paired with its own Thermal Care remote condenser.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Central Chiller | Remote Condenser | 10 to 158 Tons | 18 |
Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.
Eighteen models, single or dual circuit. The TSER010S to TSER080S carry one refrigeration circuit and the TSER020D to TSER160D two, each with two scroll compressors per circuit into stainless steel brazed plate evaporators.
Every model has a matched condenser. Thermal Care's series table pairs each TSER with a KCM or KCL remote air-cooled condenser, from the two-fan KCM014 on the TSER010S to the twelve-fan KCL224 on the TSER160D, and lists the refrigerant discharge and liquid line sizes.
Capacity is published at a 50°F set point, 60°F return and 95°F condenser air, from 10 tons on the TSER010S to 158 tons on the TSER160D, on R-410A or R-454B, with a 20 to 80°F set point range.
The same tank options as the water-cooled TSE. A standard reservoir of 275 to 1,000 gallons or a high-flow reservoir of 400 to 1,000 gallons, each with process and chiller pumps, sized with the chiller.
Scroll compressors indoors, matched remote condensers outdoors, and no tower water to treat.
Request a Quote
A remote air-cooled TSE gives a plant central chilled water without a cooling tower, its water treatment or its winter freeze-up risk. The chiller, tank and pumps stay in the mechanical room; the condensers go on the roof or a pad, and the refrigerant lines between them become part of the plant.
On a dual-circuit TSER each circuit has its own lines; for the TSER160D Thermal Care lists 2-1/8 inch discharge and 1-5/8 inch liquid connections. Line length and lift affect capacity and oil return, and a replacement is the time to decide whether the old condensers and lines are reused or replaced with the chiller. The indoor vs outdoor installation guide covers the trade-offs.
Every part-number page below names the Temptek air-cooled chilling module we supply in its place, with a remote condenser, the same amount of circuits where Temptek builds it, and sized to cover the published 50°F capacity.