1-805-484-2992

Quotes - Sizing - Sales

TSER100D

Thermal Care
Product Type Capacity Refrigerant
Central Chiller Remote Condenser 98 Tons @ 50°F R-454B or R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n TSER100D as shown on this page.

Replacement chiller for the Thermal Care TSER100D

Description

The Thermal Care TSER100D is a scroll central chiller with a remote air-cooled condenser from the Accuchiller TSE Series. Thermal Care publishes it at 98 tons (345 kW) at 50°F set point, 60°F return, 95°F condenser air, with a 20 to 80°F set point range. It runs 2 scroll compressors on each of two refrigeration circuits, on R-454B or R-410A. An integral tank is an option: 700 gallons with process and chiller pumps as standard, or 1,000 gallons on the high-flow package. Thermal Care pairs it with the KCL137 remote air-cooled condenser. Replacement: we supply the Temptek MA-105-RC-CCC, an air-cooled chilling module with a remote condenser rated 103 tons at 50°F, against the 98 tons Thermal Care publishes for this unit at 50°F. Both makers rate at 50°F leaving fluid, so the comparison is like for like. It is refrigeration only, like this chiller without its tank option, and works with a pump-tank station. It keeps more than one refrigeration circuit, as this unit has.

Product Overview

Part Number:
TSER100D
Manufacturer:
Thermal Care
Replacement Unit:
Temptek MA-105-RC-CCC

Published Capacity

Cooling Capacity:
98 tons (345 kW)
Rating Basis:
50°F set point, 60°F return, 95°F condenser air
Set Point Range:
20 to 80°F

Configuration & Specifications

Compressor:
Scroll
Compressors:
2 + 2 on two circuits
Refrigeration Circuits:
Two
Refrigerant:
R-454B or R-410A
Condenser:
Remote Air-Cooled
Evaporator:
Stainless Steel Brazed Plate
Controls:
PLC, Color Touch Screen

Pump & Reservoir

  • Tank Option, Standard Flow: 700 gallons, 15/5 hp process / chiller pumps
  • Tank Option, High Flow: 1,000 gallons, 30/5 hp process / chiller pumps

Electrical

  • Voltage: 460V
  • Phase: Three Phase
  • Frequency: 60 Hz
  • Minimum Circuit Ampacity: 162 A
  • Maximum Overcurrent Protection: 175 A

Connections

Process Connections:
4 in
Refrigerant Discharge Line:
1-5/8 in
Refrigerant Liquid Line:
1-1/8 in
Remote Condenser:
KCL137
Condenser Fans:
8

Dimensions & Weight

Dimensions (L x W x H):
113 x 49 x 68 in
Shipping Weight:
3,129 lbs (1,419 kg)
Operating Weight:
3,269 lbs (1,483 kg)

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales