1-805-484-2992

Quotes - Sizing - Sales

ACWC-1080-GC-EXCH

Cold Shot
Product Type Capacity Refrigerant
Portable Chiller Continuous Flow 90 Tons @ 50°F R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ACWC-1080-GC-EXCH as shown on this page.

Replacement chiller for the Cold Shot ACWC-1080-GC-EXCH

Description

The Cold Shot ACWC-1080-GC-EXCH is an air-cooled continuous flow chiller for an open-loop process with an external tank, from the ACWC Reverse and Continuous Flow line. Cold Shot publishes it at 1,080,000 Btu/h, 90 tons, at 50°F leaving fluid and 95°F ambient. Its stainless centrifugal process pump is listed at 7-1/2 hp, 225 GPM at 35 PSI. Cold Shot lists it for 230 V three-phase or 460 V three-phase power, with 4 in flange process connections. Replacement: we supply the Temptek TTI-100A, an air-cooled central chiller rated 90 tons at 50°F, against the 90 tons Cold Shot publishes for this unit at 50°F leaving fluid and 95°F ambient. Both makers rate at 50°F leaving fluid, so the comparison is like for like. It is a central chiller rather than a portable, because the largest Temptek air-cooled portable, the CG-30A (29 tons), falls short of this rating. It is a closed-loop unit with its own tank; on an open trough or gravity-fed loop, tell us how the return reaches the chiller and we set up the piping for it.

Product Overview

Part Number:
ACWC-1080-GC-EXCH
Manufacturer:
Cold Shot
Replacement Unit:
Temptek TTI-100A

Published Capacity

Cooling Capacity:
1,080,000 Btu/h (90 tons)
Rating Basis:
50°F leaving fluid, 95°F ambient

Configuration & Specifications

Compressor:
Scroll
Refrigerant:
R-410A
Condenser:
Air-Cooled
Style:
Continuous Flow
Pump and Tank:
Pump on board, external tank (open loop)
Controls:
PLC with self-diagnostics; WiFi / LAN / LTE for the Guardian app

Pump & Reservoir

  • Process Pump: 7-1/2 hp
  • Pump Flow: 225 GPM at 35 PSI

Electrical

  • Voltage Options: 230V three-phase / 460V three-phase
  • Frequency: 60 Hz

Connections

Process Connections:
4 in flange, inlet and outlet

Specifications sourced from Cold Shot Chillers' published Chiller Specifications page, per-size chiller pages and EZ Chiller page (waterchillers.com), September 2026. Cold Shot Chillers, EZ Chiller and Guardian are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales