1-805-484-2992

Quotes - Sizing - Sales

PWC1200D-T

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 121.4 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWC1200D-T as shown on this page.

Replacement chiller for the Drake PWC1200D-T

Description

The Drake PWC1200D-T is a 120 hp dual-circuit screw packaged water-cooled chiller, from the PWC Screw line. Drake publishes a capacity table for it rather than a single rating: 121.4 tons at 55°F leaving fluid and 95°F on the condenser column on R407C, at an EER of 13.6. The same column runs from 58.7 tons at 20°F to 143.1 tons at 65°F. It is offered on R407C for a 10°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists two RC2-180B compressors of 460 hp each. Replacement: we supply the Temptek TTI-120W, a water-cooled central chiller rated 127.8 tons at 50°F, against the 121.4 tons Drake publishes for this unit at 55°F leaving fluid and 95°F on the condenser column on R407C. The warmest condenser column is used, so the pick errs on the large side; we confirm it with your water temperature.

Product Overview

Part Number:
PWC1200D-T
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-120W

Published Capacity

Cooling Capacity:
121.4 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F on the condenser column, R407C
Capacity at 20°F Leaving Fluid:
58.7 tons
Capacity at 35°F Leaving Fluid:
83.3 tons
Capacity at 45°F Leaving Fluid:
101.5 tons
Capacity at 65°F Leaving Fluid:
143.1 tons
R404A Low-Temperature Range:
48.3 tons at 0°F to 139.4 tons at 55°F
R407C Suction Range:
10°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
120 HP
Compressor:
Screw
Compressor Model:
2 x RC2-180B, 460 hp each
Circuits:
Dual
Condenser:
Water-Cooled
Refrigerant:
R407C or R404A

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Connections

Process Connections:
4 in NPT

Dimensions & Weight

Dimensions (L x W x H):
160 x 54 x 87 in max
Weight:
3,000 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992