Replacement unit for the Drake PWC Screw Series

PWC Screw Series

Drake's largest water-cooled chillers: two screw compressors on dual circuits, 80 to 200 hp, stepped from 25 to 100%.

PRODUCT TYPE CAPACITY MODELS
Packaged Chiller Water-Cooled Packaged 80 to 200 HP 7

Specifications


Configuration & Size

Horsepower:
80 to 200 hp
Models:
7 part numbers
Capacity:
70.5 to 214 tons at 55°F
Circuits:
Dual
Refrigerant:
R407C, R404A

Construction

  • Two screw compressors
  • Stepped capacity 25 to 100%
  • Water-cooled condensers
  • Electronic expansion valves
  • NEMA 3R electrical

Ratings

  • Tables from 20 to 65°F leaving
  • 75 to 95°F condenser columns
  • R407C or R404A
  • Power: 208-230, 460, 575 V

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

PWC Screw Water-Cooled Chillers, 80 to 200 HP

Central Capacity on Tower Water

Seven models on two screws each. The PWC800D-T to PWC2000D-T carry two screw compressors on independent circuits with water-cooled condensers and stepped capacity control from 25 to 100%.

Capacity is tabulated from 20 to 65°F. The sheets list five condenser columns, 75 to 95°F, labeled COND; the 95°F column, the lowest capacity, is used for the replacement.

The tables reach low temperature. Each sheet runs from 20 to 65°F leaving fluid on R407C and from 0 to 55°F on R404A, with a 10 to 55°F R407C suction range.

Voltage choices. The PWC1200D-T is listed on 208-230, 460 or 575 V three-phase.



insulated refrigerant suction lines

Dual screw compressors on tower water, for a central process plant.

Request a Quote

PWC Screw Series Applications

Tower-water plants
Tower-water plants
Dual-circuit redundancy
Dual-circuit redundancy
Central process loops
Central process loops
Low-temperature glycol
Low-temperature glycol

schematic of the PWC Screw series circuit, showing where the process fluid and the condenser heat go

Tower and Chiller Together

A 200 hp water-cooled chiller pushes a lot of heat into the tower loop, and a replacement is the time to check the tower, the condenser pump and the water treatment as well as the chiller. A scaled condenser costs capacity and raises head pressure on the new unit as much as the old one.

The tonnage and capacity guide covers the load, and the indoor vs outdoor installation guide the water-cooled against air-cooled choice.

Every part-number page below names the Temptek unit we supply in its place, a Temptek TTI water-cooled central chiller to 180 tons, and above that the add-on module range on our sister site.
Call and talk it through with an engineer: 1-805-484-2992

Tower-Side Questions on Drake PWC Screw Chillers

Drake does not say: the sheets label five columns, 75 to 95°F, as COND without stating whether that is condensing temperature or entering condenser water. The difference matters. If it means entering water, the 95°F column we match on is conservative, since tower water usually runs cooler than that; if it means condensing temperature, real tower conditions may run hotter than any column on the sheet, and the published figures would flatter the unit. We read the 95°F column because it gives the lowest capacity either way, then confirm the selection against your actual summer tower supply temperature, which is the number to send.

Close to 2 million BTU/hr of process heat at its published 165.8 tons, before the compressors' own heat is added: 165.8 x 12,000 is 1,989,600 BTU/hr. At a 10°F range across the condenser, the process heat alone takes about 400 GPM of tower water by the 500 x GPM x delta-T rule, and the motor heat pushes the real figure higher. Before a swap, confirm the cooling tower, its pump and the strainers can carry that flow at summer conditions. A tower that was marginal for the old unit stays marginal for the new one, and it shows up as high head pressure trips on the hottest afternoons.

Usually a colder process then the 50°F match assumes, because Drake's R404A tables for the PWC -T run from 0 to 55°F while the R407C tables stop at 20°F. A plant that ordered R404A may have been holding glycol near or below 20°F at some point. On the PWC1200D-T, the R404A sheet lists 48.3 tons at 0°F, against 121.4 tons at 55°F on R407C, so a replacement picked from the warm figure would overstate that duty about 2.5 times. Before anything is matched, find out what set point the unit holds today and what glycol concentration is in the loop.

Because the TTI-180WD water-cooled central chiller is rated 178 tons at 50°F: enough for the PWC1600D-T at 165.8 tons, with 12.2 tons to spare, but 3.1 tons short of the PWC1800D-T's published 181.1. We do not stretch a selection over a shortfall, even a small one. The PWC1800D-T and the 214.4-ton PWC2000D-T are supplied as add-on chiller modules for plant-wide systems, which also lets the plant keep part of its capacity running while one module is serviced.