1-805-484-2992

Quotes - Sizing - Sales

PWC1400D-T

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 136.2 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWC1400D-T as shown on this page.

Replacement chiller for the Drake PWC1400D-T

Description

The Drake PWC1400D-T is a 140 hp dual-circuit screw packaged water-cooled chiller, from the PWC Screw line. Drake publishes a capacity table for it rather than a single rating: 136.2 tons at 55°F leaving fluid and 95°F on the condenser column on R407C, at an EER of 13.6. The same column runs from 65.9 tons at 20°F to 160.6 tons at 65°F. It is offered on R407C for a 10°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists two RC2-200B compressors of 460 hp each. Replacement: we supply the Temptek TTI-150WD, a water-cooled central chiller rated 147 tons at 50°F, against the 136.2 tons Drake publishes for this unit at 55°F leaving fluid and 95°F on the condenser column on R407C. The warmest condenser column is used, so the pick errs on the large side; we confirm it with your water temperature.

Product Overview

Part Number:
PWC1400D-T
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-150WD

Published Capacity

Cooling Capacity:
136.2 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F on the condenser column, R407C
Capacity at 20°F Leaving Fluid:
65.9 tons
Capacity at 35°F Leaving Fluid:
93.5 tons
Capacity at 45°F Leaving Fluid:
113.9 tons
Capacity at 65°F Leaving Fluid:
160.6 tons
R404A Low-Temperature Range:
53.4 tons at 0°F to 154.1 tons at 55°F
R407C Suction Range:
10°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
140 HP
Compressor:
Screw
Compressor Model:
2 x RC2-200B, 460 hp each
Circuits:
Dual
Condenser:
Water-Cooled
Refrigerant:
R407C or R404A

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Dimensions & Weight

Dimensions (L x W x H):
186 x 54 x 87 in
Weight:
3,800 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales