1-805-484-2992

Quotes - Sizing - Sales

PWC370Q-Z

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 40.9 Tons @ 55°F R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWC370Q-Z as shown on this page.

Replacement chiller for the Drake PWC370Q-Z

Description

The Drake PWC370Q-Z is a 36 hp tandem-circuit tandem scroll packaged water-cooled chiller, from the PWC / PWCT Scroll line. Drake publishes a capacity table for it rather than a single rating: 40.9 tons at 55°F leaving fluid and 85°F entering condenser water on R407C, at an EER of 491. The same column runs from 18.4 tons at 20°F to 45.3 tons at 60°F. Drake lists four ZR108KCE compressors of 9 hp each. Replacement: we supply the Temptek TTI-50W, a water-cooled central chiller rated 50 tons at 50°F, against the 40.9 tons Drake publishes for this unit at 55°F leaving fluid and 85°F entering condenser water on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F. It is a central chiller rather than a portable, because the largest Temptek water-cooled portable, the CG-40W (40 tons), falls short of this figure.

Product Overview

Part Number:
PWC370Q-Z
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-50W

Published Capacity

Cooling Capacity:
40.9 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 85°F entering condenser water, R407C
Capacity at 20°F Leaving Fluid:
18.4 tons
Capacity at 35°F Leaving Fluid:
26.4 tons
Capacity at 45°F Leaving Fluid:
33.1 tons
Capacity at 60°F Leaving Fluid:
45.3 tons
R407C Suction Range:
10°F to 55°F

Configuration & Specifications

Horsepower:
36 HP
Compressor:
Tandem Scroll
Compressor Model:
4 x ZR108KCE, 9 hp each
Circuits:
Tandem
Condenser:
Water-Cooled
Refrigerant:
R407C

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Connections

Process Connections:
2 in F-NPT

Dimensions & Weight

Dimensions (L x W x H):
95 x 34 x 42 - 77 in max
Weight:
3,600 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales