Filtrine Chiller Models

Three Filtrine styles, from a 1/4 hp bench unit to a twin 40 hp

Contact us

The Storage-Tank Chiller

Three Filtrine styles, 35 sizes each, 105 part numbers, from a 1/4 hp bench unit to a twin 40 hp chiller. Each one is listed with its published capacity and the unit we supply in its place.

Filtrine builds in Keene, New Hampshire, and has made chillers around one idea since 1925: a storage-type cooling tank, welded stainless with an immersion coil evaporator inside, in place of the brazed plate or shell-and-tube evaporator most makers use. Filtrine says the tank resists freeze-up and fouling and lets the compressor run only as needed. Every size comes in three styles: PCP closed loop, POC open loop and PC one pass. Filtrine's chart lists each size at three outlet temperatures, 30, 50 and 68°F, all at 90°F ambient, and names the model after the 68°F figure. The figures on these pages are Filtrine's own.

  • PCP closed-loop chillers recirculate a sealed coolant at constant pressure and flow.
  • Thirty-five sizes, 1,800 to 720,000 Btu/h at 50°F outlet.
  • POC open-loop chillers pump from an open tank or sump and back to it.
  • Same sizes and capacities as the PCP, with the thermostat on the make-up liquid.
  • PC one-pass chillers have no pump: the liquid passes through once.
  • Used for ingredient water, rinses and sample cooling.
  • Sizes from 5000-540 up are remote-condenser only.
105
part numbers, three styles sharing one chart
1/4 to 40 hp
compressor size, bench unit to twin
68°F
outlet temperature behind the model number
90°F
ambient Filtrine publishes capacity at
Replacement unit for the Filtrine PCP Closed Loop Series

PCP Closed Loop Series:

Closed Loop, Recirculating

  • 35 part numbers
  • 1,800 to 720,000 Btu/h
  • Sealed stainless storage tank
Replacement unit for the Filtrine POC Open Loop Series

POC Open Loop Series:

Open Loop, Recirculating

  • 35 part numbers
  • 1,800 to 720,000 Btu/h
  • Pumps from an open sump
Replacement unit for the Filtrine PC One Pass Series

PC One Pass Series:

One Pass, No Pump

  • 35 part numbers
  • 1,800 to 720,000 Btu/h
  • Liquid passes through once

Reading a Filtrine Part Number

The letters are the style. PCP is a closed-loop recirculating chiller, POC an open-loop one, PC a one-pass chiller with no pump. The three share a chart row: PCP-75-7, POC-75-7 and PC-75-7 are the same size.

The first number is roughly the compressor horsepower times 100, and the second is the capacity in thousands of Btu/h at 68°F outlet: a 75-7 has a 3/4 hp compressor and makes 7,600 Btu/h at 68°F; a 1000S-140 has a 10 hp compressor and makes 140,000. A G or S after the first number marks a compressor variant of the same frame, which Filtrine's sheets describe as scroll on G models and field-serviceable semi-hermetic on S models.

A suffix gives the condenser. -A is fan-cooled indoors, -W water-cooled, -AR a remote air-cooled condenser and -A-WP a weather-resistant outdoor build. The chart capacities are for the air-cooled models.

Replacing a Filtrine Chiller

We do not sell Filtrine equipment. We supply new Temptek chillers, and every Filtrine part-number page names the Temptek unit we would put in its place, sized to cover Filtrine's published capacity at 50°F outlet. Filtrine rates at 90°F ambient and Temptek at 95°F, the harder condition, so the pick keeps a margin. Small sizes map to a Temptek CF fractional-ton unit, mid sizes to a Temptek CG air-cooled portable, the 4000-430 to a TTI central chiller, and the remote-condenser sizes to a Temptek MA module with a remote condenser.

Read the 50°F figure, not the model number. The number in a Filtrine model is its 68°F capacity, and at 50°F the same unit makes a fifth to two fifths less. The style matters too: a Temptek replacement is a recirculating chiller, so an open-loop or one-pass installation needs its piping looked at. Before quoting we ask for the nameplate model and serial, the style and condenser suffix, the set point, the flow, and the voltage.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from Filtrine's published Process Chillers Specifications chart and per-model spec sheets (filtrine.com), October 2026. Filtrine is a trademark of its owner; referenced here for cross-reference only. Filtrine notes that dimensions and shipping weights vary with options. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More