Product Type Capacity Refrigerant
Glycol Chiller Modular Base 16.3 Tons @ 40°F R-448A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-20H-MS as shown on this page.

Replacement chiller for the G&D GD-20H-MS

Description

The G&D Chillers GD-20H-MS is a modular base glycol chiller with an oversized reservoir from G&D's Modular Series. G&D publishes it at 196,000 Btu/h at 40°F leaving glycol (about 16.3 tons), 160,000 at 30°F, 128,000 at 20°F, in a 90°F ambient, on R-448A. It carries two 10 HP compressors, a 500-gallon reservoir and a 7.5 HP process pump delivering 230 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-30S-CG-1P, an outdoor air-cooled packaged chiller rated 28.8 tons at 50°F, about 11.5 tons at 20°F on Temptek's published 0.40 multiplier, against the 10.7 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-20H-MS
Manufacturer:
G&D Chillers
Series:
Modular Series
Replacement Unit:
Temptek TTOACS-30S-CG-1P

Published Capacity

Capacity at 40°F Leaving Fluid:
196,000 Btu/h (57.4 kW)
Capacity at 30°F Leaving Fluid:
160,000 Btu/h (46.9 kW)
Capacity at 20°F Leaving Fluid:
128,000 Btu/h (37.5 kW)
Rating Basis:
90°F ambient

Configuration & Specifications

Compressor:
10 HP (x2)
Refrigerant:
R-448A
Condenser:
Air-Cooled
Evaporator:
Stainless Steel Brazed Plate
Controls:
Multi Stage Digital
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
70 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 500 Gallons
  • Process Pump: 7.5 HP
  • Chiller Pump: 1.5 HP
  • Process Flow: 230 GPM at 25 PSI
  • Connection Size: 3"

Electrical

  • Voltage: 230V / 460V
  • Phase: Three Phase
  • Full Load Amps: 102 (230V) / 54 (460V)
  • Minimum Circuit Ampacity: 111 (230V) / 58 (460V)
  • Maximum Overcurrent Protection: 145 (230V) / 75 (460V)

Dimensions & Weight

Dimensions (W x L x H):
48" x 120" x 87"
Operating Weight:
7,600 lbs
Shipping Weight:
3,300 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.