Modular Series

A base chiller with an oversized tank and a pump sized for the future: G&D's Modular Series, 10 to 27 HP, built to take Expansion Modules later.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Modular Base Unit 10 to 27 HP 4

Specifications


Configuration & Size

Capacity:
10 to 27 HP
Models:
4 part numbers
Compressor:
One or two per unit
Process Flow:
150 to 230 GPM
Refrigerant:
R-448A

Construction

  • Oversized insulated glycol reservoir
  • Auxiliary ports for expansion modules
  • Oversized process pump
  • Separate chiller pump
  • ETL 508A listed control panel

Ratings

  • Rated at 20, 30 and 40°F glycol
  • 90°F ambient
  • Refrigerant R-448A
  • Power: 230/3, 460/3

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Modular Series Base Chillers, 10 to 27 HP

Buy the Tank Now, the Capacity Later

Four base units. The GD-10H-MS and GD-13.5H-MS carry one compressor, the GD-20H-MS and GD-27H-MS two. What sets them apart from the Single and Multi Stage units is the plant around the compressor: a reservoir of 230 to 500 gallons with auxiliary ports, and a 5 to 7.5 HP process pump delivering 150 to 230 GPM.

The two larger units are fully published: the GD-20H-MS at 128,000 to 196,000 Btu/h and the GD-27H-MS at 157,000 to 230,000 Btu/h across 20 to 40°F, in a 90°F ambient, on R-448A, on 230 V or 460 V three-phase.

The two smaller sheets are not. The GD-10H-MS and GD-13.5H-MS sheets carry electrical headings without figures and no capacity table, so those pages show the product-page figures only.

The design is a growth plan. A brewery that expects to double its cellar buys the base unit with the tank and pump for the final size, then adds Expansion Modules to the ports as the tanks arrive.



plate heat exchanger and sanitary stainless piping in a bright plant

Oversized tank, oversized pump, ports for more refrigeration: the chiller that is sized for next year.

Request a Quote

Modular Series Applications

Phased plant expansion
Phased plant expansion
Growing breweries
Growing breweries
Large glycol reservoirs
Large glycol reservoirs
Central glycol loops
Central glycol loops

schematic of the Modular series circuit, showing where the process fluid and the condenser heat go

The Base Unit Carries the Plant

In a modular G&D system the base unit does two jobs. Its compressor chills the reservoir like any packaged unit, and its tank and process pump serve the whole plant loop, including the capacity the Expansion Modules add later. Each module draws from the base tank, chills that glycol and returns it.

That puts the whole plant on one pump and one tank. When one of these is replaced, check the process pump and reservoir against the plant as it is now, with every module installed, not against the base unit's original compressor size.

Each part-number page below names the Temptek outdoor unit we supply in its place. Where modules are already installed, the replacement can be a Temptek outdoor chiller sized for the combined load, or a pump-tank station with Temptek chilling modules.
Call and talk it through with an engineer: 1-805-484-2992

Replacing a G&D Modular Base Unit

Far more than the base unit's own compressors make, which is the point of the design. On the water formula, the 150 GPM pump at a 10°F rise carries about 750,000 Btu/h, roughly 62 tons, and the 230 GPM pump about 96 tons. The GD-27H-MS itself is published from 157,000 Btu/h at 20°F to 230,000 at 40°F, about 13 to 19 tons, so the pump has room for several modules on the same loop; glycol carries somewhat less heat per gallon than water, which trims those figures. The mistake on replacement is matching only the base unit's tons and ending with a pump that cannot serve the modules or the plant header.

No, about 15.4 tons. It is rated 38.4 tons at 50°F, and Temptek's published 0.40 multiplier brings that to 15.4 at 20°F, about 17 percent over the 13.1 tons G&D publishes for the GD-27H-MS there. That makes it the right pick for the base unit on it's own. With modules on the auxiliary ports, add their capacities at 20°F to the 13.1 tons before choosing. Two modules adding, say, 6 tons each would put the plant near 25 tons at 20°F, well past the 15.4 tons one TTOACS-40S-CG-1P carries there. If the total runs past what one outdoor package carries, a pump-tank station feeding several Temptek chilling modules keeps the same grow-later layout. Tell us how many modules are installed and their sizes.

A measured load and the nameplate, with the rating confirmed on request, because G&D publishes no capacity for either unit and a figure scaled down from the larger models would be a guess. Record supply and return temperature at the base tank together with the header flow on a full-load day; on the water formula, for example, 150 GPM at a 4°F rise is 300,000 Btu/h, about 25 tons, a little less on glycol. That is the load the plant really carries, modules included, and it matters more than the base unit's compressor. Send it with the reservoir volume, the pump horsepower and the modules installed.