1-805-484-2992

Quotes - Sizing - Sales

GD-140H-4C

G&D Chillers
Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 92.6 Tons @ 40°F R-454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-140H-4C as shown on this page.

Replacement chiller for the G&D GD-140H-4C

Description

The G&D Chillers GD-140H-4C is a packaged glycol chiller on semi-hermetic compressors from G&D's Vertical Air Series. G&D publishes it at 1,111,000 Btu/h at 40°F leaving glycol (about 92.6 tons), 889,600 at 30°F, 697,200 at 20°F, in a 90°F ambient, on R-454C. It carries four 35 HP compressors, a 700-gallon reservoir and a 10 HP process pump delivering 340 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-150D-MZC-2P, an outdoor air-cooled packaged chiller rated 145.8 tons at 50°F, about 58.3 tons at 20°F on Temptek's published 0.40 multiplier, against the 58.1 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-140H-4C
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek TTOACS-150D-MZC-2P

Published Capacity

Capacity at 40°F Leaving Fluid:
1,111,000 Btu/h (325.6 kW)
Capacity at 30°F Leaving Fluid:
889,600 Btu/h (260.7 kW)
Capacity at 20°F Leaving Fluid:
697,200 Btu/h (204.3 kW)
Rating Basis:
10°F temperature difference, 90°F ambient, sea level

Configuration & Specifications

Compressor:
35 HP (x4)
Refrigerant:
R-454C
Condenser:
Air-Cooled Vertical Discharge
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
81 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 700 Gallons
  • Process Pump: 10 HP
  • Chiller Pump: 2 HP
  • Process Flow: 340 GPM at 25 PSI
  • Connection Size: 4"

Electrical

  • Voltage: 460-480V
  • Phase: Three Phase
  • Full Load Amps: 296
  • Minimum Circuit Ampacity: 312
  • Maximum Overcurrent Protection: 350

Dimensions & Weight

Dimensions (W x L x H):
96" x 220" x 114"
Operating Weight:
17,500 lbs
Shipping Weight:
11,500 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales