1-805-484-2992

Quotes - Sizing - Sales

ICEP003-W

Parker Hannifin
Product Type Capacity Refrigerant
Process Chiller Air-Cooled 0.94 Tons nominal R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ICEP003-W as shown on this page.

Replacement chiller for the Parker Hannifin ICEP003-W

Description

The Parker ICEP003-W is a Hyperchill Plus compact chiller with a non-ferrous hydraulic circuit, a 15-liter tank and a 3 bar pump. Parker lists 3.3 kW, about 0.94 tons, at 20/15°C water and 25°C ambient on R407C. By Parker's correction factors that is about 0.73 tons at 10°C water and 35°C ambient. Replacement: we supply the Temptek CF-.75A, a fractional-ton portable chiller rated 0.75 tons at 50°F, against the 0.73 tons Parker Hannifin publishes for this unit at 10°C (50°F) water and 35°C (95°F) ambient. Parker rates the Hyperchill Plus at 15°C water and 25°C ambient and publishes correction factors of 0.87 for 10°C water and 0.89 for 35°C ambient; the figure compared is the nominal capacity times both, which is Temptek's rating point. Parker calls the factors approximate, so we confirm the pick at your set point. The Temptek unit is built for North American 460 V / 60 Hz or 230 V supply, not 50 Hz.

Product Overview

Part Number:
ICEP003-W
Manufacturer:
Parker Hannifin
Replacement Unit:
Temptek CF-.75A

Published Capacity

Nominal Cooling Capacity:
3.3 kW (0.94 tons)
Rating Point:
20/15°C water, 25°C ambient, 0% glycol
At 10°C Water, 35°C Ambient:
0.73 tons (nominal x 0.87 x 0.89, Parker's correction factors)
Operating Limits:
Ambient 5 to 48°C; water outlet 0°C minimum

Configuration & Specifications

Compressor:
1 hermetic piston, 1 circuit
Compressor Absorbed Power:
1.3 kW
SEPR HT:
4.50
Refrigerant:
R407C
Axial Fans:
1
Air Flow:
1,295 m³/h
Sound Pressure at 10 m:
52 dB(A)
Protection Index:
IP33

Pump & Reservoir

  • Pump: P30, 3 bar standard
  • Pump Max Power: 0.4 kW
  • Water Flow (nominal / max): 0.6/1.9 m³/h
  • Tank Capacity: 15 liters (4 gallons)

Electrical

  • Power Supply: 230 V / 1 ph / 50 Hz

Connections

Water Connections:
3/4 in

Dimensions & Weight

Width:
755 mm
Depth:
535 mm
Height:
801 mm
Weight (axial fans):
80 kg

Specifications sourced from Parker Hannifin's published Hyperchill bulletins (parker.com), October 2026. Parker, Hiross and Hyperchill are trademarks of their owner; referenced here for cross-reference only. Capacities are Parker's figures at the rating point shown. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales