PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 2.27 Tons @ 30°F R448A/R449A/R454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PE103BCR8100-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PE103BCR8100-A-V

Description

The PRO PE103BCR8100-A-V is a packaged air-cooled glycol chiller from PRO Refrigeration's ChilStar line, with a 3 hp compressor rating on the data sheet and a 100-gallon tank. PRO publishes estimated capacity at 90°F ambient: 22,100 Btu/h at 20°F, 24,500 Btu/h at 25°F, 27,200 Btu/h at 30°F, 30,100 Btu/h at 35°F leaving glycol. Air cooled with Danfoss Maneurop and Emerson hermetic reciprocating and scroll compressors, per PRO's specification. Single stainless steel centrifugal pump configuration. Replacement: we supply the Temptek CG-4A, an air-cooled portable chiller rated 4 tons at 50°F, against the 2.27 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 2.27 tons call for at least 3.78 tons of Temptek 50°F rating.

Product Overview

Part Number:
PE103BCR8100-A-V
Manufacturer:
PRO Refrigeration
Series:
ChilStar Series
Replacement Unit:
Temptek CG-4A

Published Capacity

Capacity at 20°F, 90°F Ambient:
22,100 Btu/h (1.84 tons)
Capacity at 25°F, 90°F Ambient:
24,500 Btu/h (2.04 tons)
Capacity at 30°F, 90°F Ambient:
27,200 Btu/h (2.27 tons)
Capacity at 35°F, 90°F Ambient:
30,100 Btu/h (2.51 tons)
Capacity at 25°F, 100°F Ambient:
21,000 Btu/h
Capacity at 30°F, 100°F Ambient:
23,100 Btu/h
Capacity at 35°F, 100°F Ambient:
25,400 Btu/h

Configuration & Specifications

Compressor (data sheet):
3 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A/R454C
Evaporator:
Brazed Plate
Controls:
Electronic
Electrical Enclosure:
NEMA 4
Sound Level:
56 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 1 HP
  • Process Pump: Not fitted
  • Tank: 100 gallons

Electrical

  • MCA / MOP at 230/1/60: 39 / 62 A
  • MCA / MOP at 230/3/60: 13 / 20 A
  • MCA / MOP at 460/3/60: 28 / 43 A

Connections

Glycol Connections:
1.5 in

Dimensions & Weight

Dimensions:
55 inL x 38 inW x 68 inH
Shipping Weight:
1100 lbs
Operating Weight:
1800 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.