1-805-484-2992

Quotes - Sizing - Sales

PE105BCR8100-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 3.23 Tons @ 30°F R448A/R449A/R454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PE105BCR8100-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PE105BCR8100-A-V

Description

The PRO PE105BCR8100-A-V is a packaged air-cooled glycol chiller from PRO Refrigeration's ChilStar line, with a 5 hp compressor rating on the data sheet and a 100-gallon tank. PRO publishes estimated capacity at 90°F ambient: 31,800 Btu/h at 20°F, 35,100 Btu/h at 25°F, 38,800 Btu/h at 30°F, 42,600 Btu/h at 35°F leaving glycol. Air cooled with Danfoss Maneurop and Emerson hermetic reciprocating and scroll compressors, per PRO's specification. Single stainless steel centrifugal pump configuration. Replacement: we supply the Temptek TTOACS-7.5S-CG-1P, an outdoor air-cooled packaged chiller rated 7.8 tons at 50°F, against the 3.23 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 3.23 tons call for at least 5.38 tons of Temptek 50°F rating.

Product Overview

Part Number:
PE105BCR8100-A-V
Manufacturer:
PRO Refrigeration
Series:
ChilStar Series
Replacement Unit:
Temptek TTOACS-7.5S-CG-1P

Published Capacity

Capacity at 20°F, 90°F Ambient:
31,800 Btu/h (2.65 tons)
Capacity at 25°F, 90°F Ambient:
35,100 Btu/h (2.92 tons)
Capacity at 30°F, 90°F Ambient:
38,800 Btu/h (3.23 tons)
Capacity at 35°F, 90°F Ambient:
42,600 Btu/h (3.55 tons)
Capacity at 25°F, 100°F Ambient:
28,600 Btu/h
Capacity at 30°F, 100°F Ambient:
31,700 Btu/h
Capacity at 35°F, 100°F Ambient:
34,900 Btu/h

Configuration & Specifications

Compressor (data sheet):
5 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A/R454C
Evaporator:
Brazed Plate
Controls:
Electronic
Electrical Enclosure:
NEMA 4
Sound Level:
56 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 1 HP
  • Process Pump: Not fitted
  • Tank: 100 gallons

Electrical

  • MCA / MOP at 230/1/60: 47 / 75 A
  • MCA / MOP at 230/3/60: 16 / 26 A
  • MCA / MOP at 460/3/60: 35 / 56 A

Connections

Glycol Connections:
1.5 in

Dimensions & Weight

Dimensions:
55 inL x 38 inW x 68 inH
Shipping Weight:
1000 lbs
Operating Weight:
1700 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales