PB220F10R4CL-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 24.67 Tons @ 30°F Not published

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB220F10R4CL-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PB220F10R4CL-A-V

Description

The PRO PB220F10R4CL-A-V is a 40 hp packaged glycol chiller from PRO's legacy Classic line, on two compressors of 20 hp each. PRO's legacy table lists estimated capacity at 90°F ambient: 260,600 Btu/h at 25°F, 296,000 Btu/h at 30°F, 335,000 Btu/h at 35°F leaving fluid. Its circulation pumping is two 2 HP, with two 2 in glycol field connections. Replacement: we supply the Temptek TTOACS-50S-CG-1P, an outdoor air-cooled packaged chiller rated 42.7 tons at 50°F, against the 24.67 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 24.67 tons call for at least 41.12 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB220F10R4CL-A-V
Manufacturer:
PRO Refrigeration
Series:
Classic Series
Replacement Unit:
Temptek TTOACS-50S-CG-1P

Published Capacity

Capacity at 25°F, 90°F Ambient:
260,600 Btu/h (21.72 tons)
Capacity at 30°F, 90°F Ambient:
296,000 Btu/h (24.67 tons)
Capacity at 35°F, 90°F Ambient:
335,000 Btu/h (27.92 tons)

Configuration & Specifications

Total Horsepower:
40 HP
Compressors:
2 ea / 20 HP
Frame:
Coated steel
Housing:
Galvanized sheet metal

Pump & Reservoir

  • Circulation Pump: 2 ea 2 HP

Electrical

  • MCA / MOP at 230/3/60: 183/246 A
  • MCA / MOP at 460/3/60: 92/124 A

Connections

Glycol Field Connection:
2 ea 2 in

Dimensions & Weight

Dimensions (L x W x H):
132 x 91 x 87 in
Shipping Weight:
5,000 lbs
Operating Weight:
5,200 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales