PB240F20R4CL-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 54.5 Tons @ 30°F Not published

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB240F20R4CL-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PB240F20R4CL-A-V

Description

The PRO PB240F20R4CL-A-V is a 80 hp packaged glycol chiller from PRO's legacy Classic line, on two compressors of 40 hp each. PRO's legacy table lists estimated capacity at 90°F ambient: 580,000 Btu/h at 25°F, 654,000 Btu/h at 30°F, 734,000 Btu/h at 35°F leaving fluid. Its circulation pumping is two 5 HP, with two 2 in glycol field connections. Replacement: we supply the Temptek TTOACS-120D-MZC-2P, an outdoor air-cooled packaged chiller rated 110.1 tons at 50°F, against the 54.5 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 54.5 tons call for at least 90.83 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB240F20R4CL-A-V
Manufacturer:
PRO Refrigeration
Series:
Classic Series
Replacement Unit:
Temptek TTOACS-120D-MZC-2P

Published Capacity

Capacity at 25°F, 90°F Ambient:
580,000 Btu/h (48.33 tons)
Capacity at 30°F, 90°F Ambient:
654,000 Btu/h (54.5 tons)
Capacity at 35°F, 90°F Ambient:
734,000 Btu/h (61.17 tons)

Configuration & Specifications

Total Horsepower:
80 HP
Compressors:
2 ea / 40 HP
Frame:
Coated steel
Housing:
Galvanized sheet metal

Pump & Reservoir

  • Circulation Pump: 2 ea 5 HP

Electrical

  • MCA / MOP at 230/3/60: 405/555 A
  • MCA / MOP at 460/3/60: 209/287 A

Connections

Glycol Field Connection:
2 ea 2 in

Dimensions & Weight

Dimensions (L x W x H):
180 x 91 x 87 in
Shipping Weight:
7,300 lbs
Operating Weight:
7,500 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.