1-805-484-2992

Quotes - Sizing - Sales
Replacement unit for the Trane Ascend ACS Series

Ascend ACS Series

Trane's larger scroll chiller: the Ascend ACS, 140 to 230 nominal tons, with four or six compressors on two circuits.

PRODUCT TYPE CAPACITY MODELS
Air-Cooled Scroll Chiller Packaged, Air-Cooled 140 to 230 nominal tons 6

Specifications


Configuration & Size

Capacity:
140 to 230 nominal tons
Models:
6 part numbers
Refrigerant:
R-454B
Circuits:
2
Weight:
7,754 to 10,523 lb shipping

Construction

  • Four or six scroll compressors
  • Brazed plate evaporator
  • Microchannel condenser coils
  • EC or AC condenser fans
  • R-454B refrigerant

Ratings

  • AHRI 550/590 nominal size
  • Standard leaving fluid 40 to 68°F
  • Process option below 40°F
  • Low ambient to -20°F

Specifications sourced from Trane's published product catalogs CG-PRC017AA-EN and AC-PRC002K-EN (tranetechnologies.com), October 2026. Trane, CGAM, Ascend and Symbio are trademarks of Trane Technologies; referenced here for cross-reference only. Sizes are Trane's nominal tons; rated performance comes from Trane's selection data. Confirm against the unit nameplate before ordering.

Ascend ACS, 140 to 230 Nominal Tons

Scroll Compressors at Screw-Chiller Size

Six sizes. 140 and 160 tons with four compressors; 180, 200, 215 and 230 tons with six, all on two refrigerant circuits.

Long frames. The frame is 88 inches wide and 228.8 to 334.4 inches long, at 7,754 to 10,523 lb shipping weight.

Process duty. Standard leaving fluid is 40 to 68°F; a low-temperature process version runs below 40°F with glycol.

Flow range. Evaporator flow from 168 GPM minimum on the 140 to 828 GPM maximum on the 230, through 4-inch connections.



rolled blueprints on a table

Four or six scroll compressors on two circuits, with microchannel condenser coils and 37.5-inch fans.

Request a Quote

Ascend ACS Series Applications

Plant chilled water
Plant chilled water
Data centers
Data centers
Plant-wide molding
Plant-wide molding
Outdoor pads
Outdoor pads

schematic of the Ascend ACS series circuit, showing where the process fluid and the condenser heat go

Past a Single Process Chiller

Divided by 0.80, the Ascend ACS from the 160-ton size up calls for more than any single Temptek outdoor chiller makes. Those pages point to the add-on module range on our sister site, where modules are paired to the load. The glycol chiller sizing guide works the load before anyone picks a size.

Every part-number page below names the Temptek unit we supply in its place, sized from Trane's nominal tons on Temptek's 0.80 multiplier at 40°F, or points to the add-on module range where the size is past a single chiller.
Call and talk it through with an engineer: 1-805-484-2992

Selection Notes on the Trane Ascend ACS

About 13 tons of 50°F rating. Trane's 140 tons is a nominal AHRI size at 44°F leaving water; on the 0.80 factor Temptek publishes for 40°F it calls for 175 tons, and the unit we supply is rated 188. Run at 40°F, that unit makes roughly 150 tons, 10 more than the ACS140's badge. The ACS140 is the only Ascend size one Temptek outdoor chiller covers: the ACS160 already asks for 200 tons and the ACS230 for 287.5, so those go to add-on modules for plant-wide systems to 300 tons. If your ACS140 runs Trane's low-temperature process version under 40°F, send the set point it holds and the unit is rated there.

About 30 tons on either one, since both bottom out on a single 30-ton compressor. The ACS140 steps 21, 43, 71 and 100 percent, and 21 percent of 140 is roughly 29 tons; the ACS180 runs three 30-ton compressors per circuit in six steps, the first at 17 percent, or about 31 tons. Below that, the old chiller has been starting and stopping its smallest compressor, which shows in the service log as frequent starts. Tell us the lowest load you run for long periods, because a replacement that unloads further can matter more then its peak rating.

That a full 140-ton load at that flow would need about a 20°F temperature range across the evaporator. For water, 140 tons is 1,680,000 BTU/hr, and dividing by 500 x 168 gives 20°F; at a 10°F range the same load needs 336 GPM. At the other end, 828 GPM, the ACS230's maximum, carries 230 tons at under 7°F. So the published limits bracket the duty, but your measured GPM and supply and return temperatures are what show the real load. Take them at peak and send them with the model number.

The layout, mainly. The old chiller is one 88-inch-wide frame as long as 334.4 inches, up to 10,523 lb shipping, with a single pair of 4-inch water connections. A set of add-on modules paired to the load has to be arranged on the pad and joined by a common header, so the pipe entry points, the clearances between units and the electrical feed all get laid out fresh. The ACS230 calls for 287.5 tons of 50°F rating, inside the 300-ton plant-wide range. Send the pad dimensions, where the chilled-water lines come up and the feeder size, and the module arrangement is drawn around them. That sequence also lets the header be prefabricated while the old unit is still running, so the cutover itself stays short.


Ascend ACS Units


Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales