Replacement unit for the York YLAA R-454B Series

YLAA R-454B Series

The current-refrigerant YLAA: the same Style B frames on R-454B, 39.0 to 221.7 nominal tons.

PRODUCT TYPE CAPACITY MODELS
Air-Cooled Scroll Chiller Packaged, Low-GWP 39.0 to 221.7 nominal tons 24

Specifications


Configuration & Size

Capacity:
39.0 to 221.7 nominal tons
Models:
24 part numbers
Refrigerant:
R-454B
Circuits:
2
Supply:
200 to 575 V, 3 ph, 60 Hz

Construction

  • Hermetic scroll compressors
  • Two refrigerant circuits
  • Brazed plate evaporator
  • R-454B refrigerant
  • Low-sound 2 HP condenser fans

Ratings

  • AHRI 550/590 nominal rating
  • EER 9.9 to 11.9
  • IPLV 14.9 to 17.4
  • Air on condenser to 125°F

Specifications sourced from Johnson Controls' published YLAA engineering guide, Form 150.72-EG6 (docs.johnsoncontrols.com), October 2026. York and YLAA are trademarks of Johnson Controls; referenced here for cross-reference only. Capacities are the guide's nominal ratings under AHRI 550/590. Confirm against the unit nameplate before ordering.

YLAA on R-454B, 39.0 to 221.7 Tons

The Same Frames on a Lower-GWP Refrigerant

Twenty-four models. Eight standard-efficiency SJ models, thirteen high-efficiency HJ models and three ZJ models.

Slightly lower ratings. A YLAA0125HJ is rated 116.2 tons against 118.0 for the R-410A YLAA0125HE, at a higher EER of 10.5.

Smaller charges. The R-454B charge per circuit is lower: 59 and 55 lb on the 0125HJ against 70 and 66 lb on the 0125HE.

The ZJ models. The 0070ZJ, 0100ZJ and 0155ZJ carry larger charges and a 0°F minimum air temperature; the guide does not define the Z.



white sanitary gaskets, O-rings and a tri-clamp on a steel bench

Hermetic scroll compressors on two R-454B circuits, a brazed plate evaporator and single-row condenser coils.

Request a Quote

YLAA R-454B Series Applications

Low-GWP duty
Low-GWP duty
Chilled water
Chilled water
Brewery glycol
Brewery glycol
Outdoor pads
Outdoor pads

schematic of the YLAA R-454B series circuit, showing where the process fluid and the condenser heat go

R-454B Is an A2L Refrigerant

R-454B is mildly flammable, class A2L, and the guide lists UL 60335-2-40 refrigerant detector requirements among the approvals. That affects where the chiller can sit. The indoor vs outdoor installation guide covers siting.

Every part-number page below names the Temptek unit we supply in its place, sized from York's nominal tons on Temptek's 0.80 multiplier at 40°F, or points to the add-on module range where the size is past a single chiller.
Call and talk it through with an engineer: 1-805-484-2992

York YLAA on R-454B: Siting and Sizing Questions

Using Temptek's 40°F multiplier of 0.80, the 39-ton YLAA0041HJ calls for 48.75 tons of 50°F rating and the 95-ton YLAA0100SJ for 118.75. We supply the TTOACS-60S-CG-1P at 55.1 tons and the TTOACS-150D-MZC-2P at 145.8 in their place. At 40°F those work out to about 44 and 117 tons, both above York's nominal figure, which is an AHRI number at 44°F leaving water. The YLAA0170SJ and YLAA0230HJ come out past any single Temptek unit and are covered with add-on chiller modules. Below 40°F, give us the set point, since the multiplier stops there.

From the one on your nameplate, because they differ: the R-454B YLAA0125HJ is rated 116.2 tons and the R-410A YLAA0125HE 118.0. The 1.8-ton gap is small, but it moves the Temptek requirement by 2.25 tons once divided by 0.80. One slip to watch for is a plant that swapped an HE for an HJ and kept the old 118-ton figure in its records. Better still, size from the load the loop carries, since both ratings are 44°F figures.

By working from the figures the nameplate and guide do give, not from a guess at the letter. The guide lists three ZJ models (0070ZJ, 0100ZJ, 0155ZJ) with larger refrigerant charges than the other R-454B units and a 0°F minimum air temperature. That floor is the practical point: if the site sees air colder than 0°F, a ZJ was already outside its listed range in winter, and the replacement should be picked for the real low. Send a photo of the full nameplate with its rated tons, the charge and the winter low at the pad. The gap in York's nomenclature is noted on the quote, not filled in with an assumption, and the match rests only on the published capacity.

About 114 lb, the 59 and 55 lb charges on its two circuits added together. The R-410A YLAA0125HE on the same frame holds 136 lb, so the newer unit is lighter on refrigerant, while the three ZJ models carry more then the rest of the R-454B range. R-454B carries an A2L (mildly flammable) safety class, so the recovery technician should know that before arriving, and the work belongs on the schedule as its own step ahead of disconnection. Book it early: a crew waiting on recovery is downtime the process pays for.