YLAA Series

York's air-cooled scroll chiller on R-410A: the YLAA Style B, 39.5 to 221.7 nominal tons in standard and high efficiency.

PRODUCT TYPE CAPACITY MODELS
Air-Cooled Scroll Chiller Packaged, Air-Cooled 39.5 to 221.7 nominal tons 21

Specifications


Configuration & Size

Capacity:
39.5 to 221.7 nominal tons
Models:
21 part numbers
Refrigerant:
R-410A
Circuits:
2
Supply:
200 to 575 V, 3 ph, 60 Hz

Construction

  • Hermetic scroll compressors
  • Two refrigerant circuits
  • Brazed plate evaporator
  • Single-row condenser coils, 20 fins per inch
  • Low-sound 2 HP condenser fans

Ratings

  • AHRI 550/590 nominal rating
  • EER 9.7 to 11.6
  • IPLV 15.3 to 17.5
  • Air on condenser -10 to 125°F

Specifications sourced from Johnson Controls' published YLAA engineering guide, Form 150.72-EG6 (docs.johnsoncontrols.com), October 2026. York and YLAA are trademarks of Johnson Controls; referenced here for cross-reference only. Capacities are the guide's nominal ratings under AHRI 550/590. Confirm against the unit nameplate before ordering.

YLAA on R-410A, 39.5 to 221.7 Tons

Twenty-One Models in Two Efficiency Levels

Standard efficiency. Eight models, YLAA0070SE to YLAA0170SE, rated 71.0 to 170.1 tons with EER of 9.7 to 10.4.

High efficiency. Thirteen models, YLAA0041HE to YLAA0230HE, rated 39.5 to 221.7 tons with EER of 9.8 to 11.6.

Scroll compressors in sets. Four, five or six compressors of 10 to 40 nominal tons each, split across two circuits.

Glycol duty. Standard leaving liquid is 40 to 55°F; the optional low temperature glycol kit takes it down to 10°F. Below about 20°F that kit goes past the floor of the Temptek units we supply, so a YLAA held that cold needs its own rating, not the 50°F part-number match.



a steam trap on stainless piping over a wet plant floor

Hermetic scroll compressors on two circuits, a brazed plate evaporator and single-row condenser coils.

Request a Quote

YLAA Series Applications

Chilled water
Chilled water
Brewery glycol
Brewery glycol
Plastics molding
Plastics molding
Outdoor pads
Outdoor pads

schematic of the YLAA series circuit, showing where the process fluid and the condenser heat go

R-410A Units Are Now the Ones Being Replaced

R-410A is being phased down, and the same guide now lists every YLAA on R-454B as well. A YLAA on R-410A that needs a major repair is a natural point to compare a replacement. The leaving fluid temperature guide shows why the set point has to be part of that comparison.

Every part-number page below names the Temptek unit we supply in its place, sized from York's nominal tons on Temptek's 0.80 multiplier at 40°F, or points to the add-on module range where the size is past a single chiller.
Call and talk it through with an engineer: 1-805-484-2992

Operating Questions: York YLAA on R-410A

By the last letter: E means R-410A and J means R-454B, as in YLAA0070SE or YLAA0125HE against their J-suffix counterparts. The letter before it gives the efficiency level, S for the eight standard-efficiency models and H for the thirteen high-efficiency ones. Record the full model, not just the tonnage, because the two efficiency ranges overlap: S models run 71.0 to 170.1 tons and H models 39.5 to 221.7, so a mid-range figure could belong to either. A plant with several YLAA units may have both refrigerants on site, and each is matched from its own nameplate.

From the load at its real set point, not the nominal tons on the badge. Without the kit a YLAA leaves 40 to 55°F, with it as low as 10°F, but every nominal rating in the guide is an AHRI figure at 44°F leaving water. A unit holding a 25°F brewery loop on that kit has been delivering much less than its badge, so swapping in the same nominal size on paper leaves you guessing. Temptek's 0.80 multiplier is published for 40°F; colder duties get a call for rating. Measure flow and temperature drop at peak, or send York's original selection printout if the order file still has one. Either gives the true duty at the set point, and that is what the replacement is sized against.

Because the two figures sit on different rating points: York's 170.1 tons is an AHRI nominal at 44°F leaving water, while Temptek rates at 50°F. On Temptek's 0.80 multiplier the 0170SE needs about 213 tons of 50°F rating, past any single unit, so it is covered with add-on chiller modules, as is the 221.7-ton 0230HE at about 277. Matched number for number, the TTOACS-190D-MZC-2P would make only about 136 tons at 40°F. That unit is the right pick lower down: the 120-ton YLAA0120SE needs 150 tons, which its 170.1 covers with 20 to spare. At the small end, the 39.5-ton 0041HE needs 49.4 and gets the TTOACS-60S-CG-1P at 55.1.