1-805-484-2992

Quotes - Sizing - Sales

ICS Cool Energy i-Chiller Models

Eight i-Chiller lines, from a 1.2 kW Compact n to a 1.3 MW Max e

Contact us

European Process Chillers in kW

Eight i-Chiller lines, 96 part numbers, from a 1.2 kW Compact n to a 1.3 MW Process Max e. Each one is listed with its published capacity and the unit we supply in its place.

ICS Cool Energy sells the i-Chiller range for process cooling in the UK and Europe, and publishes it the European way: a nominal cooling capacity in kW, efficiency as EER and SEPR, and 400 V / 50 Hz supply, with 230 V on the smallest units. The range runs from the Compact, Compact e and propane Compact n, through the packaged i-Chiller Process and Process e with built-in tanks, to the large Process Max e and propane Process Max n, and the ammonia Process LTn for deep freezing. The figures on these pages are ICS's own; ICS states the rating point only on the Compact n datasheet, 12/7°C water at 35°C ambient under EN 14511.

  • Compact, Compact e and Compact n run 1.2 to 16.4 kW with a tank on board.
  • Compact n uses R290 propane; Compact runs on 230 V single-phase.
  • i-Chiller Process runs 5.7 to 154.7 kW with a 60 to 678-liter tank.
  • Process e runs 5 to 190 kW on R513A to 16.6 kW and R454B above.
  • Process Max e runs 219 to 1,303 kW in HE and SHE versions.
  • Process Max n runs 165 to 242 kW on R290; LTn is an ammonia deep-freeze line.
96
i-Chiller part numbers in eight lines
1.2 kW-1.3 MW
Compact n up to Process Max e
3.517
kW per ton used to convert ICS figures
400 V / 50 Hz
European supply that changes on a swap
Replacement unit for the ICS Cool Energy i-Chiller Compact Series

i-Chiller Compact Series:

Compact, 230 V

  • 4 part numbers
  • 1.7 to 4.5 kW
  • 15 or 22-liter tank
Replacement unit for the ICS Cool Energy i-Chiller Compact e Series

i-Chiller Compact e Series:

Compact e, 400 V

  • 7 part numbers
  • 4.2 to 16.4 kW
  • 80 to 160-liter tank
Replacement unit for the ICS Cool Energy i-Chiller Compact n Series

i-Chiller Compact n Series:

Compact n, R290

  • 4 part numbers
  • 1.2 to 3.0 kW
  • 12/7°C, 35°C ambient
Replacement unit for the ICS Cool Energy i-Chiller Process Series

i-Chiller Process Series:

Packaged, With Tank

  • 18 part numbers
  • 5.7 to 154.7 kW
  • 60 to 678-liter tank
Replacement unit for the ICS Cool Energy i-Chiller Process e Series

i-Chiller Process e Series:

Packaged, Low-GWP

  • 21 part numbers
  • 5.0 to 190.3 kW
  • R513A or R454B
Replacement unit for the ICS Cool Energy i-Chiller Process LTn Series

i-Chiller Process LTn Series:

Ammonia, Deep Freeze

  • 7 part numbers
  • 88 to 249 kW at -25°C
  • -12 to -30°C
Replacement unit for the ICS Cool Energy i-Chiller Process Max e Series

i-Chiller Process Max e Series:

Large, HE and SHE

  • 32 part numbers
  • 219 to 1,303 kW
  • Two circuits, four compressors
Replacement unit for the ICS Cool Energy i-Chiller Process Max n Series

i-Chiller Process Max n Series:

Large, R290 Propane

  • 3 part numbers
  • 165 to 242 kW
  • Two circuits

Reading an ICS Part Number

The digits are the size. On the Process lines the first digit is the frame and the rest a capacity step: IC220 is the smallest frame, IC780 the largest, and the Process e adds an A (R513A) or G (R454B) at the end. On the Process Max the number is close to the nominal kW divided by 3.5: an IC060n is a 206 kW unit, an IC360e HE 1,303 kW.

The letter after the number is the variant. C is Compact, Ce Compact e, n a natural-refrigerant (propane) build, e the efficiency line. HE and SHE on the Process Max e are high and super-high efficiency acoustic versions: the SHE is quieter and lists a little less capacity.

kW to tons. Divide the kW by 3.517: 206 kW is about 58.6 tons. ICS's nominal figures are at European conditions, so the tons here are a starting point, not a US rating.

Replacing an ICS i-Chiller

We do not sell ICS Cool Energy equipment. We supply new Temptek chillers, and every ICS part-number page names the Temptek unit we would put in its place. ICS rates in kW at European conditions, 12/7°C water and 35°C ambient where it says, and Temptek at 50°F leaving fluid and 95°F ambient. 7°C is 44.6°F, colder than Temptek's rating point, so each pick is sized on Temptek's published 40°F multiplier of 0.80: the ICS figure divided by 0.80. That covers the 12/7°C rating and any warmer one. The ambient is the same, 35°C being 95°F.

The electrical side changes too: an i-Chiller built for 400 V / 50 Hz is replaced by a Temptek unit for North American supply. The LTn ammonia chillers, rated at -25°C, name no unit, and the largest Process Max e sizes point to the add-on module range on our sister site. Before quoting we ask for the nameplate model and serial, the set point, the glycol mix and the site supply.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from ICS Cool Energy's published i-Chiller product pages and datasheets (icscoolenergy.com), October 2026. ICS Cool Energy and i-Chiller are trademarks of their owner; referenced here for cross-reference only. Capacities are ICS's nominal figures in kW, converted at 3.517 kW per ton. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales