Replacement unit for the ICS Cool Energy i-Chiller Compact e Series

i-Chiller Compact e Series

ICS's three-phase compact: the i-Chiller Compact e, 4.2 to 16.4 kW nominal, with an 80 to 160-liter tank.

PRODUCT TYPE CAPACITY MODELS
Compact Chiller Compact, Air-Cooled 4.2 to 16.4 kW 7

Specifications


Configuration & Size

Capacity:
4.2 to 16.4 kW nominal
Models:
7 part numbers
Circuits:
1 / 1 compressor
Tank:
80 to 160 liters
Supply:
400 V 3-phase

Construction

  • Single circuit, one compressor
  • 80 to 160-liter storage tank
  • 3/4 to 1-1/2 in Rp connections
  • 400 V three-phase
  • SEPR HT 5.00 to 5.43

Ratings

  • Nominal kW
  • EER 2.79 to 3.06
  • 400 V / 3 ph / 50 Hz
  • Rating point not stated

Specifications sourced from ICS Cool Energy's published i-Chiller product pages and datasheets (icscoolenergy.com), October 2026. ICS Cool Energy and i-Chiller are trademarks of their owner; referenced here for cross-reference only. Capacities are ICS's nominal figures in kW, converted at 3.517 kW per ton. Confirm against the unit nameplate before ordering.

i-Chiller Compact e, 4.2 to 16.4 kW

Compact, Three-Phase, With a Tank

Seven models. From the iC15Ce at 4.2 kW to the iC70Ce at 16.4 kW nominal, each on one circuit and one compressor.

Efficiency is published. EER from 2.79 to 3.06 and SEPR HT from 5.00 to 5.43.

A real tank. 80 liters on the two smallest, rising to 160 liters on the iC55Ce and iC70Ce, with 3/4 to 1-1/2-inch Rp connections.

Three-phase. All on 400 V three-phase, from 275 to 465 kg operating.



pipe wrenches and fittings laid out for an installation

Single-circuit compressor, condenser and an 80 to 160-liter tank in a compact three-phase cabinet.

Request a Quote

i-Chiller Compact e Series Applications

Plastics molding
Plastics molding
Machine tools
Machine tools
Lasers
Lasers
Small brewery cellars
Small brewery cellars

schematic of the i-Chiller Compact e series circuit, showing where the process fluid and the condenser heat go

Mind the Supply Voltage

A Compact e is a 400 V / 50 Hz machine. In North America its replacement is a unit for 460 V / 60 Hz or 230 V, and the panel feed may need changing with it. The indoor vs outdoor installation guide covers where the chiller belongs.

Every part-number page below names the Temptek unit we supply in its place, sized from ICS's nominal kW on Temptek's 0.80 multiplier at 40°F, which covers a 12/7°C rating, and built for North American supply rather than 400 V / 50 Hz.
Call and talk it through with an engineer: 1-805-484-2992

ICS Compact e: Supply, Tank and Footprint Notes

Because 16.4 kW is about 4.66 tons, and dividing by the 0.80 multiplier calls for 5.83 tons, more than the CGD-5A's 4.9. The pick moves up to the CGD-7.5A at its 7.2-ton 50°F rating, which leaves about 1.4 tons in hand. Below that the steps are small. The iC15Ce, 4.2 kW or about 1.19 tons, needs 1.49 tons and goes to the CF-1.5A; the iC20Ce takes the CG-2A, the iC30Ce the CG-3A at 2.9 tons and the iC40Ce the CG-4A. The iC50Ce and iC55Ce both fit under the CGD-5A once the multiplier is applied. If an iC70Ce is running near its full rating at a set point colder than 7°C, give us that set point, since the 1.4-ton cushion is what absorbs it.

No: a tank smooths short spikes in load but does not add tons, so an iC15Ce removes about 1.19 tons of heat however much fluid it stores. When a cellar crashes a fermenter, the cold fluid held in those 80 liters is spent quickly and the chiller is back to its own capacity. Size the replacement for the crash load itself, worked from the vessel volume, the temperature drop and the hours allowed, and treat the 80 to 160 liters on board as a guard against short cycling, not as reserve capacity.

Not directly, because ICS's EER of 2.79 to 3.06 is a 50 Hz figure at a rating point the product page does not state. It does check out against the table: the iC15Ce's 4.2 kW of cooling on 1.5 kW absorbed is a ratio of 2.8, and the iC70Ce's 16.4 kW on 5.4 kW is about 3.04. The SEPR HT of 5.00 to 5.43 is a seasonal figure under European rules, and Temptek data is published on a different basis. Compare running cost from the new unit's own power draw at your set point and ambient, and use the ICS absorbed power only as a guide to what the circuit carries today.

Only if it's footprint, height and weight suit that spot, since the two largest Compact e models take 836 x 1006 mm of floor, stand 1670 mm tall and weigh 455 and 465 kg operating. The two smallest are 738 x 752 mm and 1261 mm tall at 275 kg. Measure the clearance on the condenser air side as well as the footprint, and allow for the 80.4 to 81.6 dB(A) sound power the room is used to.

Expect adapters or some re-piping, because the Compact e uses Rp threads, from 3/4 in on the smallest model to 1 1/2 in on the iC70Ce, and Rp is a BSP-family thread that does not seal against NPT fittings. Plants that installed a European chiller often have Rp unions or hose tails right at the machine. Confirm the connection size on the replacement and have the transition fittings on hand before the swap day, so the loop is not left open while parts are found.