Replacement unit for the ICS Cool Energy i-Chiller Process Max e Series

i-Chiller Process Max e Series

ICS's large process chiller: the Process Max e, 219 to 1,303 kW nominal, in high (HE) and super-high (SHE) efficiency versions.

PRODUCT TYPE CAPACITY MODELS
Process Chiller Large, Air-Cooled 219 to 1,303 kW 32

Specifications


Configuration & Size

Capacity:
219 to 1,303 kW nominal
Models:
32 part numbers
Circuits:
2 / 4 compressors
Weight:
1,626 to 6,667 kg
Supply:
400 V 3-phase

Construction

  • Two circuits, four compressors
  • HE and SHE acoustic versions
  • MWT option to -10°C
  • Low-ambient option to -20°C
  • 400 V three-phase

Ratings

  • Nominal kW
  • EER 3.51 to 4.71
  • SEPR HT 5.24 to 6.51
  • Rating point not stated

Specifications sourced from ICS Cool Energy's published i-Chiller product pages and datasheets (icscoolenergy.com), October 2026. ICS Cool Energy and i-Chiller are trademarks of their owner; referenced here for cross-reference only. Capacities are ICS's nominal figures in kW, converted at 3.517 kW per ton. Confirm against the unit nameplate before ordering.

i-Chiller Process Max e, 219 to 1,303 kW

Sixteen Sizes, Two Versions

Thirty-two part numbers. Sixteen sizes from IC065e to IC360e, each in an HE and an SHE version; the HE lists 228 to 1,303 kW, the SHE 219 to 1,232 kW.

Two circuits, four compressors. On every size, with EER from 3.51 to 4.71 and SEPR HT from 5.24 to 6.51.

SHE is the quiet one. Sound power drops by about 7 to 8 dB(A) on the SHE against the HE of the same size, for a few percent less capacity.

Options for process duty. A medium water temperature version to -10°C outlet and a low-ambient option to -20°C. The -10°C (14°F) outlet version is colder than the roughly 20°F the Temptek line reaches, so a Max e built that way is not covered by the matches here.



insulated storage tanks in a plant room

Two circuits and four compressors in a 2,191 mm wide frame, 3 to 9.4 m long.

Request a Quote

i-Chiller Process Max e Series Applications

Plant chilled water
Plant chilled water
Plant-wide molding
Plant-wide molding
Data centers
Data centers
Outdoor pads
Outdoor pads

schematic of the i-Chiller Process Max e series circuit, showing where the process fluid and the condenser heat go

Most Sizes Leave Single-Chiller Range

Divided by 0.80, the Process Max e from the IC150e HE upward calls for more than any single Temptek unit makes; those pages point to the add-on module range on our sister site, paired to the load.

Every part-number page below names the Temptek unit we supply in its place, sized from ICS's nominal kW on Temptek's 0.80 multiplier at 40°F, which covers a 12/7°C rating, and built for North American supply rather than 400 V / 50 Hz.
Call and talk it through with an engineer: 1-805-484-2992

Process Max e in HE and SHE: Sizing Questions

Because the SHE version's 507 kW stays within what one Temptek chiller covers after the 0.80 multiplier, and the HE version's few percent of extra capacity takes it past every single unit. The SHE's 507 kW is about 144.16 tons, which calls for 180.2 tons after the 0.80 multiplier, and the TTOACS-210D-MZC-2P is rated 188 tons at 50°F. Working back, 188 tons covers up to 150.4 nominal tons, about 529 kW, while the HE of the same size is listed with the sizes that go to modules. So read the HE or SHE suffix off the nameplate, not just the size number: on this one size it decides between a single packaged chiller and a modular plant.

Modules for plant-wide systems run to 300 tons, which after the 0.80 multiplier covers about 240 nominal tons, or roughly 844 kW of Process Max e. That reaches well into the range but not to the top: the HE tops out at 1,303 kW, about 370.5 tons, which would call for 463 tons. Units that large are split across more than one system, and the arrangement depends on how the plant loads them, so it is worked out with an application specialist from the load profile, the set point and the pad space. Send the measured load as well as the nameplate, since a load well below nameplate can bring the plant back within one system.

The minimum load and how many hours a year the plant spends near it, because four compressors on two circuits let the ICS unit step down in small increments. The replacements named against the smaller sizes, the TTOACS-100D-MZC-2P for the IC065e HE and the TTOACS-120D-MZC-2P for the IC090e HE, are dual-zone outdoor packaged chillers, and above the single-unit range the load is shared across modules. Both arrangements stage, but in different steps. A plant that runs at a quarter of peak overnight needs that figure on the quote request, or the selection is made at peak alone.

Not if it actually runs that cold: -10°C is 14°F, six degrees under 20°F, the lowest leaving temperature the Temptek line covers, so a unit set there needs a low-temperature selection. The medium water temperature option sets the limit, but the set point in use maybe warmer, so read it off the controller. If it is 20°F (about -6.7°C) or above, the selection is made at that temperature, which takes more Temptek capacity than the 0.80 multiplier allows for at 40°F. Give the winter ambient too if the low-ambient option to -20°C, or -4°F, was fitted.