1-805-484-2992

Quotes - Sizing - Sales
Replacement unit for the ICS Cool Energy i-Chiller Process LTn Series

i-Chiller Process LTn Series

ICS's deep-freeze chiller: the ammonia i-Chiller Process LTn, for glycol from -12 to -30°C.

PRODUCT TYPE CAPACITY MODELS
Low-Temperature Chiller Ammonia, Deep Freeze 88 to 249 kW at -25°C 7

Specifications


Configuration & Size

Capacity:
88 to 249 kW at -25°C
Models:
7 part numbers
Refrigerant:
R717 ammonia
Compressors:
1 or 2 screws
Range:
-12 to -30°C

Construction

  • R717 ammonia, low charge
  • Semi-hermetic inverter screws
  • Stainless welded plate evaporator
  • Microchannel condenser coils
  • Ambient to 47°C

Ratings

  • Rated at -25°C leaving glycol
  • Glycol -12 to -30°C
  • Zero GWP, zero ODP
  • 400 V / 3 ph / 50 Hz

Specifications sourced from ICS Cool Energy's published i-Chiller product pages and datasheets (icscoolenergy.com), October 2026. ICS Cool Energy and i-Chiller are trademarks of their owner; referenced here for cross-reference only. Capacities are ICS's nominal figures in kW, converted at 3.517 kW per ton. Confirm against the unit nameplate before ordering.

i-Chiller Process LTn, Rated at -25°C

Ammonia for Deep Freezing

Seven models on the product page. From 88 kW to 249 kW at -25°C leaving temperature, on one or two semi-hermetic screw compressors.

Ammonia, low charge. R717 with zero GWP and zero ODP, in a stainless refrigeration circuit with a welded-plate evaporator.

Built for heat. Microchannel condenser coils with a polyester coating, rated to ambient temperatures up to 47°C.

The datasheet names more. ICS's LTn datasheet lists ICDF 030 to ICDF 100 models at -19/-25°C glycol and 35°C ambient; the product page lists iCMax N DF models.



plant maintenance tools laid out on a bench

Ammonia screw compressors, a stainless welded-plate evaporator and microchannel condensers, outdoors.

Request a Quote

i-Chiller Process LTn Series Applications

Deep freezing
Deep freezing
Cold storage
Cold storage
Dairy
Dairy
Pharmaceutical
Pharmaceutical

schematic of the i-Chiller Process LTn series circuit, showing where the process fluid and the condenser heat go

Why These Pages Name No Unit

Temptek publishes nothing at -25°C, so a tonnage comparison would be a guess. Every LTn setpoint, -12 to -30°C, is colder than the roughly 20°F where the Temptek line stops. These pages list ICS's figures and send you to an application specialist.
Call and talk it through with an engineer: 1-805-484-2992

Ammonia i-Chiller LTn: Deep-Freeze Questions

Not within the LTn's own duty: its warmest point, -12°C or about 10°F, already sits below the 20°F floor of the Temptek line, and its -25°C rating is -13°F. So every LTn replacement starts as a low-temperature selection with an application specialist. The one exception is a plant whose process has drifted warmer than the chiller was bought for. If the loop now actually runs at 20°F or above, say so and send the measured load, and that duty can be looked at on its own terms, since the LTn's kW at -25°C would no longer describe it.

Between the iCMax N DF 115 and DF 140: the three smaller models run one screw at 88, 102 and 128 kW, and the four larger run two at 142, 170, 197 and 249 kW, all at -25°C leaving. In tons that is about 25 for the DF 80 up to about 70.8 for the DF 225. The step from 128 to 142 kW adds only about 11 percent of capacity but brings a second compressor for staging, so if the plant bought a two-screw model for its turndown, tell us. The frame stays 2191 mm wide and 2423 mm tall while lenght runs from 3540 to 7500 mm, so the pad and the crane plan follow the model.

The nameplate's own ICDF rating, since the ICDF 030 to ICDF 100 on the LTn datasheet are a seperate listing from the iCMax N DF models these pages describe. ICS rates the ICDF models at -19/-25°C glycol, about -2 to -13°F, and 35°C ambient. Do not read an ICDF 100 as the 102 kW of an iCMax N DF 100 just because the numbers look alike. Send the full model code and the kW from the plate.

Plan the ammonia side as its own job: the low R717 charge has to be recovered and the machine removed by people qualified for ammonia, and the site's safety measures for it are reviewed once it goes. Zero GWP and zero ODP belong to the ICS machine, so if a corporate low-GWP target was the reason for buying it, raise that before a replacement refrigerant is accepted. The 400 V / 50 Hz supply is also specific to this unit. Give the true summer ambient at the pad as well, since ICS rates the LTn up to 47°C, about 117°F.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales