Eight Mokon lines, from an Iceman Micro to a 120-ton central

Contact us

Iceman Portables and Central Plant

Eight Mokon chiller lines, 112 part numbers, from a tabletop Iceman Micro to a 120-ton outdoor central chiller. Each one is listed with its published figures and the unit we supply in its place.

Mokon builds in Buffalo, New York, and is best known for water and oil temperature control units; its chillers sell under the Iceman name. The portables come in air-cooled and water-cooled pairs that share one table row: an AS-15 and a WS-15 are the same 15-ton Iceman SC with a different condenser. Above them sit outdoor Iceman OA units, indoor central chillers built for a separate pump tank, and outdoor central chillers to 120 tons. Mokon rates the portables at 50°F leaving fluid and 2.4 GPM per ton, against 90°F ambient air for the air-cooled units and 85°F condensing water for the water-cooled ones. The figures on these pages are Mokon's own.

  • Iceman Micro is a 3,200 Btu/h tabletop chiller on 115 V for labs and lasers.
  • Iceman SC single-circuit portables run 9,684 to 575,760 Btu/h, about 1 to 48 tons.
  • Iceman Dual Circuit portables run about 9 to 60 tons on tandem scrolls.
  • Iceman SM modulating portables run 5 to 15 tons on digital scroll compressors.
  • Iceman LT low-temperature portables are rated at 0°F, -23 to +20°F range.
  • Iceman OA outdoor chillers run about 1 to 56 tons with pump and reservoir on board.
  • Central chillers run 30 to 120 nominal tons, single or dual circuit.
  • Outdoor central chillers run about 30 to 124 tons with a tank on board.
112
part numbers in eight Mokon chiller lines
1/4-124 tons
Iceman Micro up to outdoor central
90°F
ambient for Mokon's air-cooled figures
30%
ethylene glycol behind the Iceman OA rating
Replacement unit for the Mokon Iceman Micro Series

Iceman Micro Series:

Tabletop Portable

  • 2 part numbers
  • 1/4 Ton
  • 115 V single-phase
Replacement unit for the Mokon Iceman SC Series

Iceman SC Series:

Single-Circuit Portable

  • 22 part numbers
  • 1 to 48 Tons
  • Air- or water-cooled pairs
Replacement unit for the Mokon Iceman Dual Circuit Series

Iceman Dual Circuit Series:

Dual-Circuit Portable

  • 14 part numbers
  • 9 to 60 Tons
  • Tandem scroll, to 10% turndown
Replacement unit for the Mokon Iceman SM Series

Iceman SM Series:

Modulating Portable

  • 6 part numbers
  • 5 to 15 Tons
  • Digital scroll, 10 to 100%
Replacement unit for the Mokon Iceman LT Series

Iceman LT Series:

Low-Temperature Portable

  • 14 part numbers
  • 2 to 19 Tons at 0°F
  • -23 to +20°F
Replacement unit for the Mokon Iceman OA Outdoor Series

Iceman OA Outdoor Series:

Outdoor, Air-Cooled

  • 14 part numbers
  • 1 to 56 Tons
  • Pump and reservoir on board
Replacement unit for the Mokon Central Chiller Series

Central Chiller Series:

Central, Indoor

  • 26 part numbers
  • 30 to 120 Tons
  • For a separate pump tank
Replacement unit for the Mokon Outdoor Central Chiller Series

Outdoor Central Chiller Series:

Central, Outdoor

  • 14 part numbers
  • 30 to 124 Tons
  • Tank on board, 100 to 750 gal

Reading a Mokon Part Number

The first letter is the condenser. A is air-cooled and W water-cooled, and every Iceman portable comes in both: AS-10 and WS-10, AD-30 and WD-30, ASM-5 and WSM-5, ALT-2 and WLT-2. The outdoor lines start with O: OA for the Iceman OA, OAC and OWC for the outdoor central chillers.

The letters after it are the line. S (or C on the 1-ton reciprocating unit) is the single-circuit Iceman SC, D the Dual Circuit, SM the modulating SM, LT the low-temperature LT, DLT a dual-circuit LT. On the central chillers SC and DC mean single and dual circuit: ASC40 is a 40-ton single-circuit air-cooled central chiller, WDC80 an 80-ton dual-circuit water-cooled one.

The number is nominal tons. The published Btu/h is the figure to size from: an AS-15 is listed at 175,080 Btu/h, 14.6 tons, and an AS-30 at 360,840 Btu/h, just over 30. Mokon's web tables sometimes run a footnote mark into the model name (AC-13, AD-603, OA-12); the datasheets give AC-1, AD-60 and OA-1, which is what these pages use.

Replacing a Mokon Chiller

We do not sell Mokon equipment. We supply new Temptek chillers, and every Mokon part-number page names the Temptek unit we would put in its place: the same condenser type, the smallest size that covers Mokon's published capacity, and a link to that unit's own page on this site. Both makers rate at 50°F leaving fluid. Mokon's air-cooled figures are at 90°F ambient and Temptek's at 95°F, the harder condition, so the pick keeps a margin; water-cooled units compare like for like. An Iceman portable maps to a Temptek CG portable or, where the largest Temptek portable falls short, a TTI central chiller; an Iceman OA to a Temptek outdoor packaged chiller; a central chiller to a Temptek chilling module.

Three lines need a closer look. The Iceman OA is rated on 30% ethylene glycol, and Temptek's figure is on water, so the size is confirmed with your glycol mix. The central chillers are listed in nominal tons with no rating point. The Iceman LT is rated at 0°F, where Temptek publishes nothing to match, so its pages name no unit and go to an application specialist. Before quoting we ask for the nameplate model and serial, the set point, the glycol type and mix, and the voltage.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from Mokon's published chiller product pages and series datasheets (mokon.com), October 2026. Mokon, Iceman, Full Range, Pura-Therm and Xtreme-Therm are trademarks of their owner; referenced here for cross-reference only. Mokon notes its technical data is subject to change without notice. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.