Replacement unit for the Mokon Iceman OA Outdoor Series

Iceman OA Outdoor Series

Mokon's outdoor chiller: an Iceman OA with pump and reservoir on board, rated on 30% glycol, for -20 to 95°F ambient.

PRODUCT TYPE CAPACITY MODELS
Outdoor Chiller Outdoor Air-Cooled 1 to 56 Tons 14

Specifications


Configuration & Size

Capacity:
13,580 to 671,240 Btu/h
Models:
14 part numbers
Leaving Fluid:
20 to 65°F
Process Pump:
1-1/2 to 15 hp
Voltage:
230 or 460 V, 3 phase

Construction

  • Scroll compressors (1 and 1.5-ton recip)
  • Brazed plate evaporator
  • Stainless centrifugal pump
  • Reservoir heater and thermostat
  • NEMA 4 local, NEMA 12 remote panel

Ratings

  • Rated at 50°F leaving fluid
  • 90°F ambient, 2.4 GPM/ton
  • On 30% ethylene glycol
  • -20 to 95°F ambient

Specifications sourced from Mokon's published chiller product pages and series datasheets (mokon.com), October 2026. Mokon, Iceman, Full Range, Pura-Therm and Xtreme-Therm are trademarks of their owner; referenced here for cross-reference only. Mokon notes its technical data is subject to change without notice. Confirm against the unit nameplate before ordering.

Iceman OA Outdoor Series, 1 to 56 Tons

Outside, With Its Own Reservoir

Fourteen models from OA-1 to OA-60. Mokon lists 13,580 Btu/h on the OA-1 to 671,240 Btu/h on the OA-60, at 50°F leaving fluid, 2.4 GPM per ton and 90°F ambient.

The rating is on glycol. Mokon's figures are with 30% ethylene glycol, which an outdoor loop needs anyway; the same unit on plain water would make somewhat more.

Built for the weather. A reservoir heater and thermostat, a NEMA 4 local enclosure with disconnect and E-stop, and a NEMA 12 remote panel indoors for the controller, for -20 to 95°F ambient.

Scroll above 1.5 tons. The OA-1 and OA-1.5 use reciprocating compressors; the rest are scroll. Pumps run 1-1/2 to 15 hp and reservoirs 15 to 150 gallons, on 230 or 460 V three-phase.



chilled water piping and valves in a commercial plant room

Compressor, condenser, reservoir and pump in one outdoor cabinet, with a remote control panel indoors.

Request a Quote

Iceman OA Outdoor Series Applications

Rooftop and pad installs
Rooftop and pad installs
Winter glycol loops
Winter glycol loops
Plastics plants
Plastics plants
Plant chilled water
Plant chilled water

schematic of the Iceman OA Outdoor series circuit, showing where the process fluid and the condenser heat go

Read the Glycol Into the Rating

Most chiller tables are on water. Mokon's OA table is on 30% ethylene glycol, which is the more honest figure for an outdoor loop, and it means the comparison runs the other way: Temptek's rating is on water, and on the same glycol it makes less. The replacement pages name the size that covers Mokon's number on paper, and we confirm it against your actual mix.

The glycol type and mix guide covers mixes and what they do to capacity.

Every part-number page below names the Temptek unit we supply in it's place, a Temptek outdoor packaged chiller from 7 tons, and a Temptek CG portable below that, sized to cover the published capacity.
Call and talk it through with an engineer: 1-805-484-2992

Iceman OA Outdoors: Glycol, Ambient and Enclosures

On paper it has 1.41 tons in hand, about 16 percent, since the OA-10 is published at 8.79 tons and the TTOACS-10S-CG-1P is rated 10.2 tons. Some of that is spent before the two are even level. Mokon's figure is on 30% ethylene glycol and Temptek's on water, and the Temptek unit makes less on the same glycol; how much less depends on the mix. Working the other direction, Temptek rates at 95°F ambient and Mokon at 90°F. We confirm the pick at your actual mix and set point, and at a stronger mix than 30% the headroom shrinks further.

The loop does, whatever the chiller carries: a site that sees -20°F needs a glycol mix and standby heat that hold through the coldest night, as the OA's reservoir heater and thermostat did. Tell us the lowest ambient the pad has actually seen, whether the process stops in winter and how long the loop sits idle. Ask for the replacement's cold-weather arrangement to be stated on the quote. Note where the OA's NEMA 12 remote panel sits indoors, too, because operators will expect the controls in the same place.

Not as the same kind of install: below 7 tons the pick is a CG air-cooled portable rather than an outdoor packaged chiller, so plan around a portable unless the quote says otherwise. The OA-3 is covered by the CG-3A, rated 2.9 tons; the OA-1 and OA-1.5, at 13,580 and 18,333 Btu/h, are smaller still. Moving the chiller indoors puts its condenser heat in the room. If no part of the loop stays outdoors afterward, the glycol can be set for the process alone instead of for winter, which gives back some capacity.

Give us the real figure, because 95°F is the top of the OA's published ambient range and also the ambient at which Temptek rates. A roof or a walled pad with poor airflow can run well above the weather station on a summer afternoon, and capacity falls right as the load peaks. Measure at the condenser inlet on a hot day if you can, and the selection is checked at that temperature.