Replacement unit for the Mokon Iceman Dual Circuit Series

Iceman Dual Circuit Series

Two refrigerant circuits on tandem scroll compressors: Mokon's Iceman Dual Circuit portables, 105,000 to 715,000 Btu/h.

PRODUCT TYPE CAPACITY MODELS
Portable Chiller Dual-Circuit Portable 9 to 60 Tons 14

Specifications


Configuration & Size

Capacity:
105,000 to 715,000 Btu/h
Models:
14 part numbers
Circuits:
Two, tandem scroll
Process Pump:
5 to 15 hp
60-Ton Air:
Remote condenser

Construction

  • Tandem scroll compressors
  • Two refrigerant circuits
  • Stainless brazed plate evaporator
  • Stainless centrifugal pump
  • Dixell controller, lead/lag

Ratings

  • Rated at 50°F leaving fluid
  • 90°F ambient, 2.4 GPM/ton
  • 85°F condensing water, 3 GPM/ton
  • 20 to 65°F range

Specifications sourced from Mokon's published chiller product pages and series datasheets (mokon.com), October 2026. Mokon, Iceman, Full Range, Pura-Therm and Xtreme-Therm are trademarks of their owner; referenced here for cross-reference only. Mokon notes its technical data is subject to change without notice. Confirm against the unit nameplate before ordering.

Iceman Dual Circuit Series, 9 to 60 Tons

Two Circuits for a Changing Load

Fourteen part numbers in seven pairs. AD models are air-cooled and WD models water-cooled, from 105,000 Btu/h on the AD-10 to 715,000 Btu/h on the WD-60.

The water-cooled figures are a little higher. Mokon lists the AD-30 at 336,000 Btu/h on 90°F air and the WD-30 at 347,000 Btu/h on 85°F condensing water, both at 50°F leaving fluid and 2.4 GPM per ton.

Tandem scrolls turn down to 10%. Mokon describes the tandem arrangement as giving capacity down to 10% of the total for small loads, with both circuits running together at full load.

The 60-ton air-cooled unit splits. Mokon supplies the AD-60 with a remote air-cooled condenser. Pumps run 5 to 15 hp, tanks 20 to 150 gallons, all at 20 to 65°F leaving fluid.



an industrial control panel with switches and indicator lights

Tandem scroll compressors on two circuits, a brazed plate evaporator, tank and pump in one portable frame.

Request a Quote

Iceman Dual Circuit Series Applications

Redundant cooling
Redundant cooling
Plastics molding
Plastics molding
Packaging lines
Packaging lines
Chemical process
Chemical process

schematic of the Iceman Dual Circuit series circuit, showing where the process fluid and the condenser heat go

Why Two Circuits Matter

A dual-circuit chiller is two refrigeration systems sharing one evaporator, tank and pump. If one trips, the other keeps running at about half capacity, which for many processes is the difference between a slow day and a scrapped batch. It also runs one circuit through the light-load hours instead of cycling a large compressor.

When replacing one, ask whether the plant relied on that redundancy; a single-circuit unit of the same tons is not the same machine. The glycol chiller sizing guide works the load itself.

Every part-number page below names the Temptek unit we supply in its place, a Temptek CG portable of the same condenser type, and a Temptek TTI central chiller where the largest Temptek portable falls short; the AD-60, with its remote condenser, maps to a Temptek MA module with a remote condenser.
Call and talk it through with an engineer: 1-805-484-2992

Questions We Get on Iceman Dual Circuit Units

A 10°F rise across the process at full load, since 12,000 Btu/h per ton divided by 500 x 2.4 GPM gives 10°F. On the AD-60, published at 692,000 Btu/h or about 57.7 tons, that is roughly 138 GPM through the evaporator. A loop running well below that flow at the same load sees a wider rise, so the process outlet runs warmer than the 50°F set point suggests. Measure the actual flow before the swap, and size the replacement pump for it.

About 33,600 Btu/h, or 2.8 tons, which is 10 percent of the AD-30's published 336,000 Btu/h at 50°F. A process that idles near that figure for long stretches has been carried by one compressor stage on one circuit. A replacement that cannot step down that far holds temperature by hot gas bypass or by cycling. Give us the overnight or between-batch load in tons alongside the peak, and the selection is checked at both ends.

Only if it already delivers about 179 GPM of 85°F water in summer, since the WD-60 is published at 715,000 Btu/h, about 59.6 tons, at 3 GPM per ton. A WD-30 at 347,000 Btu/h, about 28.9 tons, needs roughly 87 GPM, and a WD-10 at 109,000 Btu/h about 27. Those flows are what the tower and its pump must hold on the hottest day, not on a mild one. A short supply shows up as rising head pressure and trips on summer afternoons, often mistaken for a refrigerant fault. Check the replacement's condenser water need against the same tower before ordering.

Not necessarily, so confirm it on the quote: the AD-60 is a split system, and what replaces it is a chilling module rather than a one-piece portable. The AD-60 ships with a remote condenser, a 15 hp pump and a 150-gallon tank, and we supply the Temptek MA-60-RC-C, which also works with a remote condenser, in its place. Its 60 tons at 50°F cover the AD-60's 692,000 Btu/h, about 57.7 tons, with some 2.3 tons in hand. If the AD-60's own pump and tank are the only ones on the loop, say so, so that pumping and storage are part of the selection rather than discovered at startup.

By the AD-40 on the air-cooled side, which needs more than the largest Temptek portable makes and so takes the TTI-40A central chiller. The water-cooled WD-60 likewise goes to the TTI-60W, while smaller sizes stay on CG frames: the AD-10's 105,000 Btu/h, 8.75 tons, sits under the CGD-10A's 9.8 tons, and the WD-20 goes to the CG-20W at 20 tons. Mokon and Temptek both rate at 50°F leaving fluid, so these matches need no multiplier, and on the air-cooled side Temptek rates at 95°F ambient against Mokon's 90°F, a five-degree cushion. A TTI is a central chiller, so plan its floor space and piping as a fixed installation rather than a unit on casters.