Replacement unit for the Cold Shot WCWC Portable Water-Cooled Series

WCWC Portable Water-Cooled Series

Cold Shot's water-cooled portable: pump and tank on board, condenser heat carried off by tower or plant water, 1.5 to 100 tons.

PRODUCT TYPE CAPACITY MODELS
Portable Chiller Water-Cooled Portable 1.5 to 100 Tons 23

Specifications


Configuration & Size

Capacity:
1.5 to 100 tons at 50°F
Models:
23 part numbers
Frames:
E and GC
Process Pump:
1 to 7-1/2 hp
Refrigerant:
R-410A

Construction

  • Scroll compressors, R-410A
  • Brazed plate water-cooled condenser
  • Stainless brazed plate evaporator
  • Stainless centrifugal process pump
  • Insulated tank, bypass valve

Ratings

  • Rated at 50°F leaving fluid
  • 85°F condenser water
  • Refrigerant R-410A
  • 208-230 V single-phase to 5 tons

Specifications sourced from Cold Shot Chillers' published Chiller Specifications page, per-size chiller pages and EZ Chiller page (waterchillers.com), September 2026. Cold Shot Chillers, EZ Chiller and Guardian are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

WCWC Portable Water-Cooled Chillers, 1.5 to 100 Tons

Portable Capacity Without the Room Heat

Twenty-three models on two frames. The E frame runs 1.5 to 20 tons on the specifications page, and 25 to 70 tons on the per-size pages; the GC frame runs 25 to 100 tons on the specifications page. Each unit carries its pump and an insulated tank with a bypass flow valve.

Capacity is published at 50°F leaving fluid on 85°F condenser water, from 18,000 Btu/h on the WCWC-18-E to 1,200,000 Btu/h on the WCWC-1200-GC. Cold Shot notes that water-cooled units run at lower head pressure and are typically installed indoors.

Pumps step up with the frame. 1 hp at 30 GPM to 5 tons, 1-1/2 to 3 hp on the E frame to 20 tons, and 7-1/2 hp on everything larger: 160 GPM at 30 PSI on most units to 40 tons, and 225 to 300 GPM at 35 PSI on the GC units above.

Most large GC units are 208-230 V. The specifications page lists most GC portables, the WCWC-480-GC excepted, on 208-230 V three-phase only; the E-frame units from 7.5 tons are listed on 208-230 V or 460 V.



large diameter cooling water pipes in a plant

A water-cooled condenser, a stainless pump and an insulated tank: the portable for a plant with tower water.

Request a Quote

WCWC Portable Water-Cooled Series Applications

Tower-water plants
Tower-water plants
Plastics molding
Plastics molding
Process reactors
Process reactors
Winery tank cooling
Winery tank cooling

schematic of the WCWC Portable Water-Cooled series circuit, showing where the process fluid and the condenser heat go

Two Water Loops at the Machine

A water-cooled portable needs two connections: the process loop it chills, and a condenser water supply that carries the heat away, from a cooling tower, a plant loop or another water source. Cold Shot rates the condenser on 85°F entering water; warmer tower water in summer reduces capacity, and Cold Shot notes that condenser water needs treatment to keep mineral scale off the heat transfer surfaces.

Condenser water flow is part of the selection, roughly 3 GPM per ton on tower water, so a 100-ton unit needs a tower loop that can deliver around 300 GPM on top of the process flow. The tonnage and capacity guide covers how to count the load.

Every part-number page below names the Temptek unit we supply in it's place, sized to cover the published 50°F capacity: a Temptek CG water-cooled portable to 40 tons, and a Temptek TTI water-cooled central chiller from 50 tons.
Call and talk it through with an engineer: 1-805-484-2992

Condenser Water Questions on WCWC Portables

More than 8°F at full load on tower water at roughly 3 GPM per ton, because the compressor work leaves through the condenser along with the process heat. Each ton is 12,000 Btu/h, and 3 GPM carries 500 x 3, or 1,500 Btu/h per degree, so the cooling load alone accounts for 8°F before the compressor work is added. On 85°F entering water, the return to the tower sits above 93°F. That rise is what the tower has to be sized to take back out. A tower selected for a smaller rise, or one already near its limit on a hot afternoon, sends back warmer water, and the chiller loses capacity just when the plant is busiest.

On the 100-ton WCWC-1200-GC it is 300 GPM, delivered at 35 PSI, which holds the rise to about 8°F at full rating; a 40-ton unit moves 160 GPM for about 6°F, both on water. The 40-ton figure is 480,000 Btu/h over 80,000, which is 500 x 160; the 100-ton figure is 1,200,000 over 150,000, which is 500 x 300. Small rises mean high flow, and the GC units deliver it at 35 PSI. A molding plant that replaces one of these with a unit pumping less flow will see the rise widen and the last press on the header run warmer. Note the pump the old unit carries and the pressure the farthest load needs.

Cold Shot's per-size pages mark those rows with the air-cooled footnote rather than the water-cooled one, and the pages do not say why. Both footnotes state 50°F leaving fluid, so the leaving-fluid basis holds and we size the Temptek unit to it. What is missing is the condenser side: those rows give no 85°F condenser water figure, so the WCWC-480-E and WCWC-840-E pages show 50°F leaving fluid alone, each with a note. For a replacement, the gap only matters if your tower runs warmer than 85°F in summer; then send the hottest supply temperature and we rate at that.

Yes, if the Temptek unit is ordered for the plant's 460 V, so name that voltage at the start rather than copying the old unit's listing. Apart from the WCWC-480-GC, the GC portables are listed for 208-230 V three-phase and nothing else, so a plant running 460 V elsewhere may have fed one through a step-down transformer. Taking it out removes its losses and a failure point. Check the disconnect, not the drawing, since transformers get added and forgotten.

Up to 40 tons the match is a Temptek CG water-cooled portable; from 50 tons it is a water-cooled TTI central chiller, because the largest portable falls short. The specific matches: the CG-25W at 26 tons for the 25-ton WCWC-300-GC, the CG-40W for the WCWC-480-E, the TTI-50W for the WCWC-600-GC, the TTI-80W at 85.2 tons for both the 70 and the 80-ton sizes, and the TTI-90W for 90 tons. The headroom varies: about 4 percent on the CG-25W, about 22 percent on the TTI-80W at 70 tons and about 6.5 percent at 80. The 50°F basis is common to both makers, so those are true margins, and the thin ones deserve a second look if your tower runs warm in summer.