Compact, outdoor-rated and built for the plant floor: G&D's ForgeLine HT industrial chillers, 0.5 to 6.1 tons.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Process Chiller | Air-Cooled Industrial | 0.5 to 6.1 Tons | 7 |
Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.
Seven models, all air-cooled. G&D describes the ForgeLine as its rugged, air-cooled line for demanding manufacturing, processing and high-temperature applications. The GD-0005TFLN runs a reciprocating compressor and is for indoor use only; the six larger models run scroll compressors in an outdoor-rated, corrosion-resistant chassis.
Capacity runs from 0.5 to 6.1 tons, 1.8 to 21.5 kW, on R-513A, as listed in G&D's ForgeLine brochure. The brochure does not say at what leaving-fluid temperature or ambient those figures are rated, so treat them as nominal until the setpoint is confirmed.
Two cabinet sizes cover the range. The three smallest units sit in cabinets 82 to 88 cm wide; the four TFLR units share one 111 x 90 x 145 cm frame from 2.3 to 6.1 tons, which makes a later upsizing a like-for-like swap on the pad.
The published data stops there. G&D lists no electrical figures, pump, flow, tank, connection sizes or weights for the ForgeLine line. Those pages show what is published and nothing else; the nameplate fills the gaps.
Scroll compressors, a stainless plate evaporator and an outdoor-rated chassis in a small footprint.
Request a Quote
A ForgeLine unit is small enough to sit beside the building wall next to the machine it serves, with its condenser air on the outside and only the chilled fluid coming in. Axial fans with step control follow the load and the weather, and an inlet strainer ahead of the evaporator keeps shop debris out of the plate pack. The smallest model is the exception: it is rated for indoor use only.
Because G&D does not publish the rating temperture, check the setpoint before trusting the tonnage. A 2.3-ton figure at a 50°F water rating would be well under 2 tons on 30°F glycol. The leaving fluid temperature guide shows how quickly capacity falls with setpoint.
Each part-number page below names the Temptek unit we supply in its place, sized on the brochure tonnage: a CF fractional-ton portable for the three smallest, a CG portable to 4 tons, and a Temptek outdoor packaged unit for the GD-0061TFLR.
Call and talk it through with an engineer: 1-805-484-2992