The NQ with its condenser on the roof: 5 to 40 tons of portable chiller indoors, with the heat rejected outside through a matched remote air-cooled condenser.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Portable Chiller | Remote Condenser | 5 to 40 Tons | 9 |
Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.
Nine models, each with a named remote condenser. Thermal Care pairs every NQR with its own air-cooled condenser, from the KCM009 on the NQR05 to the KCL056 on the NQR40. The chiller carries one or two scroll compressors, the brazed plate evaporator, reservoir and pump; the condenser carries the coil and fans.
Capacity is published at 50°F leaving coolant and 95°F ambient air at the condenser: 5 tons on the NQR05 up to 40 tons on the NQR40, on R-454B or R-410A, with a 20 to 80°F set point range.
The indoor cabinet is the water-cooled one. The NQR shares the NQW's low cabinet, 53 or 47 inches tall, its 14 to 67-gallon reservoirs and its 2 to 5 hp pumps, delivering 13 GPM at 40 PSI up to 92 GPM at 40 PSI.
The refrigerant piping is part of the job. Thermal Care lists the condenser connections for each pair, 7/8-inch inlet on the smallest up to 2-5/8 inch on the largest, and those lines run from the chiller to the roof.
Indoor chiller, outdoor condenser: the heat leaves the building through a pair of refrigerant lines.
Request a Quote
A remote-condenser chiller solves the room-heat problem of an air-cooled portable without needing a tower. The cost is the refrigerant piping: a hot-gas line out to the condenser and a liquid line back, sized for the length and the lift between them. Long runs and big vertical rises need oil traps and larger lines, and they reduce capacity if they are ignored.
Before replacing one, measure the existing line run and check whether the condenser on the roof is being kept. A condenser that has been in the weather for fifteen years is usualy replaced with the chiller, and the new pair should be selected together for the refrigerant the new unit uses. The indoor vs outdoor installation guide covers where each arrangement makes sense.
Every part-number page below names the Temptek remote-condenser unit we supply in its place, sized to cover the NQR's published 50°F capacity. The NQR40 is above the largest Temptek remote-condenser portable, so its page names a Temptek air-cooled chilling module with a remote condenser.