TCF Series

A Turbocor compressor on a hybrid film evaporator: Thermal Care's TCF line, one 40 to 120-ton process chiller and one 13°F ice-rink chiller.

PRODUCT TYPE CAPACITY MODELS
Central Chiller Centrifugal Central 45 to 120 Tons 2

Specifications


Configuration & Size

Capacity:
45 to 120 Tons
Models:
2 part numbers
Compressor:
One Turbocor
Evaporator Flow:
240 GPM (350A)
Refrigerant:
R-513A

Construction

  • Turbocor variable-speed centrifugal
  • Hybrid film evaporator
  • One refrigeration circuit
  • Water-cooled condenser
  • C-UL 508A panel, rotary breaker

Ratings

  • 350A: 50°F set point, water
  • 375: 13°F set point, 40% glycol
  • Refrigerant R-513A
  • Power: 460/3/60 and 575/3/60

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

TCF Series Centrifugal Chillers

A Process Chiller and an Ice-Rink Chiller

Two models, one circuit each. The TCFW350A is a water-cooled process chiller, and the TCFW375 a water-cooled chiller built for ice rinks. Both carry a single Turbocor variable-speed centrifugal compressor on R-513A.

The evaporator is what is different. Thermal Care pairs the compressor with a hybrid film evaporator, which it describes as giving the most efficient heat transfer while minimizing the refrigerant charge.

The TCFW350A is published at 40 to 120 tons cooling water at a 50°F set point, 60°F return and 85°F condenser water, with a 40 to 75°F set point range and 240 GPM of evaporator flow at 50°F.

The TCFW375 is published at 45 to 55 tons on 40% ethylene glycol at a 13°F set point and 16°F return, with a 10 to 55°F set point range and an intended operating range of 10 to 15°F.



plant room with rows of pumps, stainless headers and flanged valves

Hybrid film evaporator, magnetic-bearing compressor, R-513A: two chillers built around the same pairing.

Request a Quote

TCF Series Applications

Ice rinks
Ice rinks
Low-temperature glycol
Low-temperature glycol
Energy-efficient chilled water
Energy-efficient chilled water
Water-cooled plants
Water-cooled plants

schematic of the TCF series circuit, showing where the process fluid and the condenser heat go

Two Very Different Set Points

The two TCF models look alike and do opposite jobs. The TCFW350A makes chilled water in the 40s and 50s for a plant header, the duty a Turbocor does best. The TCFW375 pulls glycol down to 13°F for an ice sheet, which is why it is rated on 40% ethylene glycol and why its capacity, 45 to 55 tons, is so much lower for a similar compressor.

An ice rink is also an unusual load: the brine loop runs cold for months, the heat load swings with the crowd and the resurfacing schedule, and the condenser heat is often recovered to melt snow or heat water. The glycol type and mix guide covers what a 40% mix does to flow and pump selection.

The TCFW350A page names the Temptek water-cooled central chiller we supply in its place, sized to cover the top of its published 120-ton range at 50°F. Nothing we supply is rated at the TCFW375's 10 to 15°F duty, since Temptek's range ends near 20°F, so its page sends you to an application specialist.
Call and talk it through with an engineer: 1-805-484-2992

TCF Series: Two Models, Different Questions

More than the 240 GPM Thermal Care lists, if the 10°F range of its rating point holds: 120 tons is 1,440,000 BTU/hr, and at a 50°F set point with 60°F return that takes 288 GPM. Worked the other way, 240 GPM across a 10°F range carries 1,200,000 BTU/hr, or 100 tons. So either the published flow belongs to a point below the top of the 40 to 120-ton range, or the unit runs a wider range at full capacity. Before the replacement is fixed, measure your actual flow and return temperature. Those two numbers give the real load, and the TTI-120WD selection is checked against them.

Because its published set point range stops at 40°F, while the TCFW375 is rated at 13°F on 40% ethylene glycol and built for an intended 10 to 15°F duty. The two share a Turbocor compressor and the hybrid film evaporator, but the rink unit is configured and rated for brine, which is also why it is rated at only 45 to 55 tons against the 350A's 120-ton top. A reset to 13°F is not a control change. We have no unit rated for that duty either, so for a rink, bring the load, the brine temperature and the glycol mix to an application specialist.

Thermal Care lists identical figures for both models: 229 A minimum circuit ampacity with a 400 A maximum overcurrent device at 460 V three-phase, or 184 A and 300 A at 575 V. The 575 V option carries about 20% less current, which shrinks the feeder and the disconnect. If the plant is on 575 V, say so at the start, because the replacement's electrical is confirmed at that voltage, and changing it midway means redoing the feeder, disconnect and selection.

Not necessarily: the TTI-120WD is named because Thermal Care publishes the TCFW350A as a 40 to 120-ton range, and we cover the top of it when the actual load is unknown. If your plant load is well below 120 tons, the measured load is the better basis. A 70-ton header served by a 120-ton machine, for example, spends most of its life at light load, and a smaller unit, or two that stage, may suit it better. Send the peak and minimum load, the set point and the condenser water temperture, and an application specialist sizes to those. The rating basis does not change: 50°F leaving, 60°F entering, on 85°F condenser water.