The NQ portable with its condenser on tower or plant water: 6 to 43 tons, quieter and shorter than the air-cooled units, with no heat thrown into the room.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Portable Chiller | Water-Cooled Portable | 6 to 43 Tons | 9 |
Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.
Nine models on scroll compressors. The NQW05 to NQW15 run one compressor and the NQW20 to NQW40 two, into a stainless steel brazed plate evaporator, with a water-cooled condenser in place of the microchannel coil and fans, on R-454B or R-410A.
Capacity is published at 50°F leaving coolant on 85°F condenser water. The unit pages list 6 tons on the NQW05 up to 43 tons on the NQW40, above the model numbers throughout. The set point range is 20 to 80°F.
Same tanks and pumps as the air-cooled line. Reservoirs of 14 to 67 gallons, stainless pumps of 2 to 5 hp, and flow from 13 GPM at 40 PSI up to 102 GPM at 34 PSI. Process connections step from 1-1/2 inch to 2-1/2 inch on the NQW35 and NQW40.
Lower and quieter. With no condenser fans the 20-ton and larger cabinets stand 47 inches tall rather than 94, and Thermal Care publishes 70 to 78 dBA at 1 meter.
No condenser fans, no room heat: the NQ portable for a plant with tower or process water at the machine.
Request a Quote
A water-cooled NQ needs two connections: the process loop it chills, and a condenser water supply to carry the heat away, usually from a cooling tower. Thermal Care rates the condenser at 85°F entering water, a typical tower design point; a tower that runs warmer in August, or city water that runs colder in January, moves the capacity with it.
The condenser water flow is part of the selection. On tower water it is roughly 3 GPM per ton of chiller capacity, so a 40-ton NQW needs a tower loop that can deliver well over 100 GPM at the machine, in addition to the process flow. Where there is no tower, the remote air-cooled NQR or an outdoor chiller is the better fit; the indoor vs outdoor installation guide compares the options.
Every part-number page below names the Temptek water-cooled portable we supply in it's place, sized to cover the NQW's published 50°F capacity. The NQW40, at 43 tons, is above the largest Temptek portable, so its page names a Temptek water-cooled central chiller.
Call and talk it through with an engineer: 1-805-484-2992