Replacement unit for the Thermal Care NQ Series Water-Cooled

NQ Series Water-Cooled

The NQ portable with its condenser on tower or plant water: 6 to 43 tons, quieter and shorter than the air-cooled units, with no heat thrown into the room.

PRODUCT TYPE CAPACITY MODELS
Portable Chiller Water-Cooled Portable 6 to 43 Tons 9

Specifications


Configuration & Size

Capacity:
6 to 43 Tons at 50°F
Models:
9 part numbers
Compressor:
One or two scroll
Process Flow:
13 to 102 GPM
Refrigerant:
R-454B, R-410A

Construction

  • Scroll compressors, one or two
  • Water-cooled condenser
  • Stainless brazed plate evaporator
  • Electronic expansion valve
  • Stainless process pump, poly reservoir

Ratings

  • Rated at 50°F leaving coolant
  • 85°F condenser water
  • R-454B or R-410A
  • Power: 460/3/60 published

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

NQ Water-Cooled Portable Chillers, 6 to 43 Tons

Portable Capacity Without the Room Heat

Nine models on scroll compressors. The NQW05 to NQW15 run one compressor and the NQW20 to NQW40 two, into a stainless steel brazed plate evaporator, with a water-cooled condenser in place of the microchannel coil and fans, on R-454B or R-410A.

Capacity is published at 50°F leaving coolant on 85°F condenser water. The unit pages list 6 tons on the NQW05 up to 43 tons on the NQW40, above the model numbers throughout. The set point range is 20 to 80°F.

Same tanks and pumps as the air-cooled line. Reservoirs of 14 to 67 gallons, stainless pumps of 2 to 5 hp, and flow from 13 GPM at 40 PSI up to 102 GPM at 34 PSI. Process connections step from 1-1/2 inch to 2-1/2 inch on the NQW35 and NQW40.

Lower and quieter. With no condenser fans the 20-ton and larger cabinets stand 47 inches tall rather than 94, and Thermal Care publishes 70 to 78 dBA at 1 meter.



clear blue water pouring from a PET plastic bottle

No condenser fans, no room heat: the NQ portable for a plant with tower or process water at the machine.

Request a Quote

NQ Series Water-Cooled Applications

Injection molding
Injection molding
Tower-water plants
Tower-water plants
Process reactors
Process reactors
Anodizing and plating
Anodizing and plating

schematic of the NQ series Water-Cooled circuit, showing where the process fluid and the condenser heat go

Two Water Loops at the Machine

A water-cooled NQ needs two connections: the process loop it chills, and a condenser water supply to carry the heat away, usually from a cooling tower. Thermal Care rates the condenser at 85°F entering water, a typical tower design point; a tower that runs warmer in August, or city water that runs colder in January, moves the capacity with it.

The condenser water flow is part of the selection. On tower water it is roughly 3 GPM per ton of chiller capacity, so a 40-ton NQW needs a tower loop that can deliver well over 100 GPM at the machine, in addition to the process flow. Where there is no tower, the remote air-cooled NQR or an outdoor chiller is the better fit; the indoor vs outdoor installation guide compares the options.

Every part-number page below names the Temptek water-cooled portable we supply in it's place, sized to cover the NQW's published 50°F capacity. The NQW40, at 43 tons, is above the largest Temptek portable, so its page names a Temptek water-cooled central chiller.
Call and talk it through with an engineer: 1-805-484-2992

NQ Water-Cooled: What to Know Before Sizing

Roughly 230 GPM in two separate loops: about 129 GPM of tower water to the condenser, at roughly 3 GPM per ton on the NQW40's 43 tons, plus up to 102 GPM of process flow from its own pump. Both have to be piped to the machine, and the condenser side is the one that gets overlooked; a tower branch sized for a smaller portable will starve this one, and the warning sign is head pressure climbing on warm days. The two largest sizes, NQW35 and NQW40, use 2-1/2 inch process connections. Check the tower branch size and pressure at the machine before the swap.

Only if the piping, hoses and mold passages drop less than about 34 PSI at full flow, the pressure Thermal Care publishes at the NQW40's 102 GPM, lower than the 40 PSI listed at 13 GPM on the smallest unit. That flow corresponds to about a 10°F rise at the published 43 tons: 43 x 12,000 is 516,000 BTU/hr, and 500 x 102 x 10 is 510,000. On a long header, behind quick disconnects or through small mold passages, full flow may not get through, and the symptom is a high temperature rise with the chiller only partly loaded. Measure the process pressure drop before the replacement is selected, so a booster pump can be planned if it is needed.

Because each NQW is published above its model number, and the replacement covers the published figure. The NQW30 is listed at 33 tons, beyond a 30-ton unit, so it takes the CG-40W, while the NQW25 fits under the CG-30W. The 43-ton NQW40 takes the TTI-50W, a 50-ton water-cooled central chiller. The NQW20, published at 23 tons, is sized on the same rule. Check each margin against your peak load.