Replacement unit for the PRO Refrigeration Chill&Flow Series

Chill&Flow Series

PRO's smallest current chiller: a 3/4 hp Chill&Flow with a dedicated process pump, a circulation pump and a 5-gallon tank.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Compact Packaged 3/4 HP, 6,430 Btu/h at 35°F 1

Specifications


Configuration & Size

Capacity:
5,740 Btu/h at 30°F
Models:
1 part number
Compressor:
3/4 hp
Pumps:
1/6 hp process + circulation
Tank:
5 gallons

Construction

  • Hermetic reciprocating compressor
  • Brazed plate evaporator
  • Dedicated process and circulation pumps
  • HDPE insulated tank
  • Galvanized steel frame

Ratings

  • Rated at 25 to 35°F glycol
  • 90°F and 100°F ambient
  • R448A / R449A / R454C
  • 120 or 230 V single-phase

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Chill&Flow Series, 3/4 HP

Small, With Two Pumps

One model. The PE1008B1R805-A-V is listed at 5,740 Btu/h at 30°F leaving glycol and 6,430 at 35°F, in a 90°F ambient, and 5,170 and 5,830 at 100°F.

Two pumps, not one. PRO fits a dedicated process pump and an internal circulation pump, each 1/6 hp, on a 5-gallon HDPE tank with 1-inch glycol connections.

It plugs into ordinary power. PRO lists it on 120 V or 230 V single-phase, at 25 A and 15 A MCA, in a 33 x 30 x 27-inch galvanized cabinet of about 400 lbs.

Casters are an option. PRO offers a caster set for mobile use, and lists the package as UL listed.



color-coded process piping runs in a plant

Reciprocating compressor, brazed plate evaporator, a 5-gallon tank and two pumps in one cabinet.

Request a Quote

Chill&Flow Series Applications

Brewery fermentation
Brewery fermentation
Small winery tanks
Small winery tanks
Small dairy loads
Small dairy loads
Short glycol loops
Short glycol loops

schematic of the Chill&Flow series circuit, showing where the process fluid and the condenser heat go

Read the Glycol Column

At 3/4 hp the Chill&Flow suits a few small fermenters or a short draft line. Its capacity is published at the glycol temperature, so read the column you will run: 30°F for most brewery glycol, 35°F for wine. The glycol chiller sizing guide works the load from tank volume and crash time.

Every part-number page below names the Temptek unit we supply in its place, sized from PRO's 30°F figure on Temptek's published multiplier: a Temptek unit makes 0.60 of its 50°F rating at a 30°F set point, so the pick is the PRO figure divided by 0.60.
Call and talk it through with an engineer: 1-805-484-2992

Before You Replace a PRO Chill&Flow

Yes, the CF-1A we supply is a fractional-ton portable, so a Chill&Flow that moves on PRO's optional casters can be replaced by a unit that moves too. Check the route rather than the rating: PRO's cabinet is 33 x 30 x 27 inches and about 400 lbs, so measure doorways and ramps against the CF-1A dimensions on the quote. The Chill&Flow's 1/6 hp process pump and 1-inch connections suit a short run beside the tank, so tell us if the glycol travels farther.

No, the same Temptek CF-1A covers both duties. PRO publishes 5,740 Btu/h at 30°F, 0.48 tons, which needs 0.8 tons of 50°F rating once divided by 0.60, against the CF-1A's 1 ton. At 35°F the Chill&Flow makes 6,430 Btu/h, 0.54 tons; even run through the same division, that is 0.89 tons, still inside the 1-ton rating. So a winery tank room and a brewery cellar end up on the same unit. Where the duties split is lower down: a loop held at 25°F, the bottom of PRO's rating, sits below the column the pick was built on, so give us that set point and it is rated there.

Only if the CF-1A nameplate matches that circuit, so check it before the old unit is unplugged. PRO lists the Chill&Flow two ways: 120 V single-phase at 25 A MCA, or 230 V single-phase at 15 A MCA. A 25 A minimum circuit at 120 V is more than a general-purpose receptacle is built for, so the existing outlet is likely a dedicated circuit, and its rating needs confirming. The mistakes we see run both ways: a unit that trips the breaker on its first pull-down, or a 230 V plug that simply does not fit the receptacle. Read the voltage and breaker size at the outlet, photograph the plug, and send both with the quote request.