Replacement unit for the PRO Refrigeration M5 Series

M5 Series

PRO's legacy M5: glycol chillers from 0.75 to 13.5 hp for chilled fluid from -5 to 45°F, indoors or outdoors.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Low-Temperature, Legacy 0.75 to 13.5 HP 7

Specifications


Configuration & Size

Capacity:
6,650 to 120,300 Btu/h at 35°F
Models:
7 part numbers
Range:
-5 to 45°F
Pump:
6 to 50 GPM
Tank:
5 to 100 gallons

Construction

  • Packaged air-cooled
  • Indoor or outdoor installation
  • 5 to 100-gallon tank
  • Pumps 6 to 50 GPM
  • R448 / R449 refrigerant

Ratings

  • Rated at -5 to 45°F leaving
  • 90°F air
  • R448 / R449
  • 115 V to 460 V by size

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

M5 Series, 0.75 to 13.5 HP

A Wide Temperature Table

Seven models. From the M5E1008B22R405-A-V at 3/4 hp on a 5-gallon tank to the M5M112F3R4100-A-V at 13.5 hp on 100 gallons.

Capacity from -5 to 45°F. PRO publishes six columns at 90°F air; the 13.5 hp unit makes 47,800 Btu/h at -5°F and 147,800 at 45°F. The matches here start from the 35°F column; an M5 run below about 20°F is outside the Temptek line and is rated separately.

Pumps by size. From 6 GPM at 23 ft on the smallest to 50 GPM at 189 ft on the 10 and 13.5 hp units.

Indoor or outdoor. On R448/R449, with electrical from 115 V single-phase on the smallest to 460 V three-phase.



a supermarket frozen food aisle

Packaged compressor, condenser, tank and pump for chilled fluid from -5 to 45°F.

Request a Quote

M5 Series Applications

Low-temperature glycol
Low-temperature glycol
Brewery fermentation
Brewery fermentation
Cold storage
Cold storage
Dairy
Dairy

schematic of the M5 series circuit, showing where the process fluid and the condenser heat go

The 35 Degree Column Is Used

The M5 table has no 30°F column, so its pages match on the 35°F figure with the same 0.60 multiplier; Temptek makes more than that at 35°F, so the pick keeps a margin.

Every part-number page below names the Temptek unit we supply in its place, sized from the 35°F figure divided by 0.60.
Call and talk it through with an engineer: 1-805-484-2992

Selection Notes on the PRO M5 Series

The split follows the size of the duty: the 3/4 and 3 hp M5 map to Temptek portables, and every model from 5 hp up maps to an outdoor packaged unit. The 3/4 hp M5E1008B22R405-A-V, at 6,650 Btu/h at 35°F or 0.55 tons, needs about 0.92 tons on Temptek's 50°F basis and goes to the CF-1A at 1 ton; the 3 hp goes to the CG-4A at 4 tons. At the top, the 13.5 hp makes 120,300 Btu/h, 10.03 tons, which needs 16.71 tons and lands on the TTOACS-20S-CG-1P at 18.9. The 7 hp takes the TTOACS-10S-CG-1P and the 9 and 10 hp share the TTOACS-15S-CG-1P, so the line steps up one package size at a time.

It misses the cold end entirely, because the pick is built on the 35°F figure and the M5's own output at -5°F is about 40 percent of that. The 13.5 hp M5M112F3R4100-A-V makes 47,800 Btu/h at -5°F, about 3.98 tons, against 10.03 tons at 35°F. The 3 hp model makes 12,300 Btu/h, about one ton, at -5°F. What confuses buyers is that the TTOACS-20S-CG-1P is rated 18.9 tons, which looks like ample cover for a 4-ton duty. That rating is at 50°F, and a -5°F duty has to be rated at -5°F before anyone relies on it. A loop held that far below glycol duty goes to an application specialist rather than a tonnage match.

The old unit could push glycol through a lot of piping, and the replacement has to match that head, not just the flow. The largest M5 frames deliver up to 189 ft, and the 3 to 7 hp models 76 or 114 ft. On a water basis, 50 GPM carries the 13.5 hp unit's 120,300 Btu/h at 35°F accross about 4.8°F. If a replacement pump falls short of that head, the most distant user warms first while the chiller reads fine at its own outlet. Send the loop lenght and elevation changes.

It can, but moving the chiller outdoors is a project in its own right and should be planned before the order. PRO built the M5 for indoor or outdoor installation, while every pick from 5 hp up is an outdoor packaged TTOACS unit, from the TTOACS-7.5S-CG-1P upward. An M5 that sat in a cellar beside its tanks becomes a pad outside, a supply and return run through the wall, and piping that has to be insulated against heat gain and, at low set points, condensation and frost. The longer run also adds pump head. Send the current location and any spot a pad could go, so the selection accounts for the new run as well as the load.