Replacement unit for the PRO Refrigeration V-Scroll Series

V-Scroll Series

PRO's legacy dual-scroll chillers: 20 and 30 hp on two compressors, with a 200-gallon tank and separate pumps.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Scroll, Legacy 20 and 30 HP 2

Specifications


Configuration & Size

Capacity:
199,800 and 297,400 Btu/h at 30°F
Models:
2 part numbers
Compressors:
2 x 10 or 2 x 15 hp
Pumps:
2 hp each
Tank:
200 gallons

Construction

  • Two scroll compressors
  • Coated steel frame
  • Galvanized sheet metal housing
  • 2 hp circulation and process pumps
  • 2-inch glycol connection

Ratings

  • Rated at 20 to 35°F glycol
  • 90°F ambient
  • Refrigerant not listed
  • 230 or 460 V three-phase

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

V-Scroll Series, 20 and 30 HP

Two Scrolls, One Tank

Two models. The PS210B98R4200-V-V on two 10 hp compressors and the PS215B98R4200-V-V on two 15 hp.

Capacity at the glycol temperature. The PS215 is listed at 297,400 Btu/h at 30°F and 331,200 at 35°F, at 90°F ambient; the PS210 at 199,800 and 222,200.

Separate pumps. One 2 hp circulation pump and one 2 hp process pump, on a 200-gallon tank with a 2-inch glycol connection.

The same frame. Both in a 114 x 57 x 100-inch coated steel frame with galvanized housing, about 5,000 lbs operating.



pumps and piping in a commercial plant room

Two scroll compressors, a 200-gallon tank and separate circulation and process pumps.

Request a Quote

V-Scroll Series Applications

Brewery fermentation
Brewery fermentation
Winery fermentation
Winery fermentation
Dairy cooling
Dairy cooling
Outdoor pads
Outdoor pads

schematic of the V-Scroll series circuit, showing where the process fluid and the condenser heat go

From a Published Legacy Table

PRO still publishes the V-Scroll table on its Legacy Chillers page, and the figures here are read from it. The refrigerant is not listed; check the nameplate.

Every part-number page below names the Temptek unit we supply in its place, sized from PRO's 30°F figure on Temptek's published multiplier: a Temptek unit makes 0.60 of its 50°F rating at a 30°F set point, so the pick is the PRO figure divided by 0.60.
Call and talk it through with an engineer: 1-805-484-2992

PRO V-Scroll PS210 and PS215: Changeout Questions

The 20 hp PS210B98R4200-V-V goes to the TTOACS-30S-CG-1P at 28.8 tons and the 30 hp PS215B98R4200-V-V to the TTOACS-50S-CG-1P at 42.7 tons, both 50°F ratings. PRO lists the PS210 at 199,800 Btu/h and the PS215 at 297,400, both at 30°F, or 16.65 and 24.78 tons, which call for 27.75 and 41.3 tons once divided by 0.60. Worked back to 30°F, the picks run about 0.6 and 0.8 tons above the PRO figures, a close fit on both. If the existing unit already struggles in summer, the load has probably outgrown it, and the replacement should be picked from the measured load rather than the old rating.

About 11 percent more on both models, and no, the pick stays on the 30°F figure. The PS215 rises from 297,400 to 331,200 Btu/h when the glycol is allowed up to 35°F, a gain of 33,800, and the PS210 from 199,800 to 222,200. Roughly two percent per degree is a useful sense of how sensitive these units are to set point. The trap runs the other way: a plant that drops from 35 to 30°F for a faster crash gives up about a tenth of the old unit's output and often blames the chiller. If you run at 35°F, a pick sized at 30°F carries spare capacity; if you run colder than 30°F, tell us.

Measure both on the running loop before the old unit comes out, since PRO lists the 2 hp process pump and it's 2 hp circulation partner but gives no flow or head for either. Pressure gauges on the pump's suction and discharge give the head it develops; a clamp-on flow meter or the balancing valves give the flow. Those two readings set the duty the new pumping has to meet. Without them a replacement is easy to mis-pump: too little and the farthest fermenters lag, too much and the control valves hunt. Note any jackets or tanks added since the V-Scroll went in, since the original pump may now be running far out on its curve.

Maybe, but only after the new unit's nameplate MCA and maximum breaker size are compared with it. PRO lists the PS210 at 136 A MCA at 230 V and 66 A at 460 V, and the PS215 at 192 A and 88 A. The picks differ in size, a 28.8-ton unit for the 20 hp and a 42.7-ton unit for the 30 hp, so their electrical demand will not track the old figures one for one. Both V-Scroll models sit in the same 114 x 57 x 100-inch frame at about 5,000 lbs, which makes it easy to assume the pads and services are interchangeable too. Check conductor size, the disconnect and the breaker before the order, not on delivery day.