Replacement unit for the PRO Refrigeration PROGreen CO2 Series

PROGreen CO2 Series

PRO's natural-refrigerant chiller: a 100 hp CO2 system with a 750-gallon vessel and heat recovery to 180°F hot water.

PRODUCT TYPE CAPACITY MODELS
CO2 Glycol Chiller CO2 (R744) Packaged 100 HP CO2 1

Specifications


Configuration & Size

Capacity:
791,373 Btu/h at 30°F, 90°F
Models:
1 part number
Refrigerant:
R744 (CO2)
Vessel:
750 gallons
Heat Recovery:
180°F potable water

Construction

  • 2 x 50 hp Bitzer R744 compressors
  • V Series gas coolers
  • 750-gallon dual-chamber vessel
  • VFD process pump, standby pumps
  • Danfoss electronic controls

Ratings

  • Capacity by ambient, 40 to 110°F
  • Coolant 20 to 35°F
  • Transcritical above about 75°F
  • GWP of 1

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

PROGreen CO2 Series, 100 HP

A Chiller on Natural Refrigerant

One published model. The PG-100VA750-TC-XX runs parallel 50 hp Bitzer R744 compressors, with a 750-gallon dual-chamber coolant vessel.

Capacity by ambient. PRO's table runs from 40 to 110°F ambient at 20, 25, 30 and 35°F coolant: 791,373 Btu/h at 30°F and 90°F ambient.

Subcritical, then transcritical. Above about 75°F ambient the CO2 cycle goes transcritical and capacity falls with each step of ambient.

Heat is part of the package. Onboard recovery makes 180°F potable hot water, and the process pump runs on a VFD with standby pumps.



refrigeration plant control valves on insulated lines

Two R744 compressors, V Series gas coolers, a 750-gallon vessel and heat recovery on a boxed steel frame.

Request a Quote

PROGreen CO2 Series Applications

Brewery fermentation
Brewery fermentation
Dairy plants
Dairy plants
Heat recovery
Heat recovery
Outdoor pads
Outdoor pads

schematic of the PROGreen CO2 series circuit, showing where the process fluid and the condenser heat go

Hot Summers Cost a CO2 Chiller More

A CO2 system loses more capacity in heat than a conventional one: PRO's table shows 1,221,000 Btu/h at 30°F in a 50°F ambient and 791,373 at 90°F. Size it on the summer design day.

Every part-number page below names the Temptek unit we supply in its place, sized from PRO's 30°F figure on Temptek's published multiplier: a Temptek unit makes 0.60 of its 50°F rating at a 30°F set point, so the pick is the PRO figure divided by 0.60. The 90°F ambient figure is used.
Call and talk it through with an engineer: 1-805-484-2992

Replacing a PROGreen CO2 Chiller: Key Points

It gives up onboard hot water and a refrigerant with a GWP of 1. The PG-100VA750-TC-XX runs R744 through V Series gas coolers and recovers heat into potable water at 180°F. The TTOACS-120D-MZC-2P we supply is an outdoor air-cooled packaged chiller on conventional refrigerant, so it brings neither. Before the swap, find out what that hot water feeds today, such as CIP, cleanup or brewhouse preheat. Plants often discover the dependence only when the water-heating bill jumps in the first month. If the plant has a sustainability target written around the GWP figure, raise it before the order, not after.

They leave with the PRO package, so decide early whether the plant still needs that reserve and that pump arrangement. The PROGreen carries a 750-gallon dual-chamber coolant vessel, a VFD process pump and standby pumps on its own frame. The Temptek unit is selected on tons, so vessel volume and standby pumping are separate lines on the quote, not something the model match replaces by default. A plant that counted on the standby pump to ride through a seal failure, or on the vessel to buffer a crash on several tanks at once, should say so. Give us the flow and head the VFD pump runs at today, and how often the standby pump has actually been called on.

Very thin: against a requirement of 109.92 tons, the 110.1-ton rating leaves a surplus of 0.18 tons. Worked back to 30°F, that is about 1,300 Btu/h above the 791,373 Btu/h PRO lists at 90°F ambient, under a quarter of one percent. Two things push past it. A site whose design day runs hotter than 90°F asks more of any air-cooled unit, and there is no margin left to absorb that; PRO's own table keeps falling up to 110°F. And coolant held at 20 or 25°F is a harder duty than the 30°F the pick is based on. If either applies, the selection moves up rather than being stretched, so give us the design ambient and the coolant temperature you hold.